The forced operation function cannot be memorized if power off.
7.4.7 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before
the power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24
℃
setting temp.
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
7.4.8 Refrigerant Leakage Detection
With this new technology, the display area will show
“EC” when the outdoor unit detects refrigerant
leakage.
7.4.9 8
℃
Heating(optional)
When the compressor is running, the indoor fan motor will run without anti-cold air function.
When the compressor is off, the indoor fan motor is off.