wind function has the priority.
Auto fan action:
T1-TS
Low
Medium
The indoor fan speed will adjust according to the value of T1-T
S
.
7.4.3.4 Defrosting mode
:
During the defrosting mode, the compressor keep running, indoor and outdoor motor will stop,
defrost lamp of the indoor unit will be lighted
“
.
” Will be displayed.
For
MS12F-21HR-NB8W model,
AC will enter the defrosting mode according to the value of temp. of T3 and the value range of
temp. change of T3 and also the compressor running time.
During the defrosting mode, the compressor keep running, indoor and outdoor motor will stop,
defrost lamp of the indoor unit will be lighted
“
.
” Will be displayed.
7.4.3.5 High evaporator coil temp.T2 protection:
When the evaporator coil temp.T2 keeps more than setting value, the compressor and outdoor fan
will shut off.
7.4.3 Auto-mode
This mode can be chosen with remote controller and the setting temperature can be changed
between 17~30
℃
.
In auto mode, the machine will choose cooling, heating or fan-
only mode according to ΔT (ΔT
=T1-Ts).