Premium Products CBW10 Installation, Operation And Maintanance Manual Download Page 11

11

remier

remier

roducts

roducts

P

P

P

P

WATER TREATMENT

®

Automatic Water Filters

1

2

3

4

Application*

Part #

Description

Qty

CBW10

CBW10D

CBW20

CBW20D

Iron Removal

135514

Birm

1 Box

1 CF

2 Boxes

2 CF

Acid Neutralizer

023357

Calcite

Sediment

135518

Filter-AG

Taste & Odor

135516

Activated Carbon

Bypass Valve Less 
Connectors 
023328

Connectors
023329
Set of 2

IL1052

Air Inducer 
CCF10 Only
021708

IL1053

Item Description

CBW10 CBW10D CBW20 CBW20D CCF10 CCF10D

CCF20

CCF20D

1

Distributor 
tube / screen

023360 023360 023488 023488 023360 023360

023488

023488

2

Mineral tank

023319 023320 023483 023491 023319 023320

023483

023491

3

Mineral

*

*

*

*

023358 023358 023358(Qty 2) 023358(Qty 2)

4

Gravel

135523 135523 023529 023529 135523 135523

023529

023529

Summary of Contents for CBW10

Page 1: ...0 CCF10D CBW20 CBW20D CCF20 CCF20D Service Flow 1 Cont GPM 3 3 5 5 Peak GPM 8 8 10 10 Pipe Size In Out Inches 1 1 1 1 Operating Pressure Range PSI 30 125 30 125 30 125 30 125 Max Operating Temperature...

Page 2: ...ng If feedwater pressure is known to be above 125 psi it is strongly recommended that a pressure reducing valve be installed at this point Unfiltered water to Sprinklers and any dersired unfiltered fi...

Page 3: ...viceability The split ring retainer design holds the nut on and allows load to be spread over the entire nut surface area reducing the chance for leakage The split ring design incorporated into the by...

Page 4: ...supply valve completely 8 Plug control valve into a non switched 115v power source 9 Manually stage filter to the backwash position see service manual 10 Open inlet valve and allow the unit to fill S...

Page 5: ...threaded plastic fittings NEVER use pipe dope as it will deteriorate the plastic fittings CHECK WATER PRESSURE Minimum water pressure required at the inlet of the filter is 20 psi IF PRESSURE IS OVER...

Page 6: ...g cooling are to be treated by the Chemical Free filter a larger model filter MUST be selected to accommodate the higher flow rate demands 4 IMPORTANT Always use Teflon tape on threaded plastic fittin...

Page 7: ...pply valve completely 8 Plug control valve into a non switched 115V power source 9 Manually stage filter to the backwash position see service manual 10 Open inlet valve and allow the unit to fill SLOW...

Page 8: ...t to backwash at a time of low water usage An example of a time with low water usage is when a household is asleep If there is a demand for water when the system is backwashing untreated water will be...

Page 9: ...l Operation The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this pos...

Page 10: ...nter clockwise to remove Turn clockwise to install Item No Part No Description Qty 1 023406 Motor 1 2 023412 PC Board 1 3 023408 Piston Assy 1 4 023409 Seal Assy 1 5 023410 O Ring Kit 1 6 127001 Miner...

Page 11: ...35516 Activated Carbon Bypass Valve Less Connectors 023328 Connectors 023329 Set of 2 IL1052 Air Inducer CCF10 Only 021708 IL1053 Item Description CBW10 CBW10D CBW20 CBW20D CCF10 CCF10D CCF20 CCF20D 1...

Page 12: ...sition d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back in to reset control valve e Motor not inserted fully to engage pinion motor w...