background image

 

 

 

 

 

Page 

8

 of 

14

  

FIGURE 4.1.2 

Bottom View

 

of Pump Drain Plug 

 

 

iv.

 

Carefully remove the drain pan and safely dispose of the collected water. 

v.

 

Close the drain valve by turning the handle 90° clockwise to be parallel with the pump 
tank. 

c.

 

On a weekly basis, unscrew the pump air intake and inspect the intake filter element. Clean or 
replace as needed.  

7.

 

Fill the tank with water and test the system per the Filling and Operating procedures. Inspect for any 
leaks/clogs and any other defects in the system. 

8.

 

If all inspections pass, empty the water from the system (see section 5.1 Emptying the Tank). 

 

4.2 Filling the Tank: 

1.

 

Make sure power is off and the HydroCleaner is unplugged. 

2.

 

Lift the top access panel. The tank will automatically begin to vent. 

3.

 

Verify the tank pressure gauge reads 0 PSI so the tank is depressurized. 

Do no proceed to the next step 

until depressurization is complete.

  

FIGURE 4.2.1 

Tank

 

Pressure Gauge 

 

 

4.

 

MAKE SURE THE TANK DRAIN VALVE IS COMPLETELY CLOSED (HANDLE IS TO BE PERPENDICULAR TO 
THE PIPE), ALLOWING THE SOLUTION TO FLOW TO THE SPRAY GUN. 

FIGURE 4.2.2 

Tank Drain Valve Closed 

  

Tank Pressure 
Gauge 

Tank drain valve in closed position.  
Valve is turned clockwise to close. 

 

Pump Drain Plug 

Rotate valve counterclockwise 
to open/drain. 

 

S1 

Summary of Contents for HydroCleaner HC-02

Page 1: ...follow instructions may result in serious injury Carefully read all instructions before use Never spray flammable caustic acidic chlorine bleach petroleum non water based or other corrosive solutions...

Page 2: ...T SPECIFICATIONS 5 3 SAFETY INFORMATION 6 4 OPERATION 7 4 1 BEFORE USE CHECKLIST 7 4 2 FILLING THE TANK 8 4 3 OPERATING PROCEDURE 9 4 4 SPRAY ADJUSTMENT 9 5 CARE INSTRUCTIONS 11 5 1 EMPTYING THE TANK...

Page 3: ...ndle Base 4 FIGURE 1 1 9 Spray Gun 4 FIGURE 4 1 1 Pump Oil Cover and Air Intake 7 FIGURE 4 1 2 Bottom View of Pump Drain Plug 8 FIGURE 4 2 1 Tank Pressure Gauge 8 FIGURE 4 2 2 Tank Drain Valve Closed...

Page 4: ...IGURE 1 1 3 Rear View w Skin L J P Q H S1 T O M K I N R FIGURE 1 1 9 Spray Gun AH AI AL AN AK AM AJ AG FIGURE 1 1 7 Side View 2 w o Skin U AB AA F H AC FIGURE 1 1 8 Handle Base AF1 AF2 AF3 AD AE FIGUR...

Page 5: ...IN VALVE AI SPRAY GUN AIR QUICK CONNECT I TANK W DOOR SWITCH AJ SPRAY HOSING COLORED AIR J POWER OFF ON SWITCH X TANK CLAMP AK SPRAY GUN AIR FLOW ADJUST KNOB K GFI POWER CORD Y TANK PRESSURE RELIEF AL...

Page 6: ...OT Do not use in hazardous environments or in the presence of flammable liquids gases or dust Beware of all hazards in area and in combination with sprayer contents Stop immediately if any unusual noi...

Page 7: ...needed 5 DO NOT USE IF ANY DEFECTS ARE FOUND 6 Make sure the pump maintenance is up to date Maintenance listed below a Check the pump crankcase oil level daily before use i For HydroCleaner models wit...

Page 8: ...the water from the system see section 5 1 Emptying the Tank 4 2 Filling the Tank 1 Make sure power is off and the HydroCleaner is unplugged 2 Lift the top access panel The tank will automatically beg...

Page 9: ...the contents of the tank into the air be sure to appropriately dispense the tank contents following all SDS and safety regulations for the solution dispensing procedures 6 Squeeze and hold the trigge...

Page 10: ...y vary a Before changing the tank pressure make sure the unit is powered on and the pump is finished running b When the tank pressure has stabilized adjust the regulator As per the Figure 4 4 3 below...

Page 11: ...the top access panel 3 Place the drain hose into an appropriate collection container in accordance with SDS instructions to capture the contents from the tank Secure the hose to the container 4 Open...

Page 12: ...in the hoses and spray gun to drain from the system 5 3 Handle Height Adjustment 1 The handle height may be adjusted to the desired level for operation and storage There are three height settings as s...

Page 13: ...ary per SDS instructions to clean any solution that may have come in contact with the equipment while the spray gun was in use 5 Unplug the unit from the outlet and carefully store with the unit 6 Loo...

Page 14: ...aid This warranty shall not be interpreted to render us liable for injury or damages of any kind or nature direct consequential or contingent to person or property This warranty does not extend any ex...