Return  

Air Plenum

Forced  Air Heating/Cooling System

Forced  Air Heating/Cooling System

To living 

space

PAGE 4

2. Information for the Installer

Special

Consideration 

For integrated system installation

• Verify  clearance  on  the  ductwork  to

mount the unit using the Forced Air   heat-

ing/cooling system

• Minimum  clearance  requirements  for

maintenance and service

• Electrical power requirements

• Interaction between the HEPA filter unit

and other mechanical devices.

Ducting Flair

System  

installation

The Whole House HEPA Filtration system is

designed to install directly onto the return

air plenum of the forced air heating/cooling

system.  Choosing  this  type  of  installation

eliminates the need to externally duct the

HEPA filter unit to the plenum system. If you

choose  this  type  of  installation,  it  is

recommended that you run the fan on your

forced air system continuously to maximize

its cleaning ability. 

TIPS 

to installer

The  Whole  House  HEPA  Filtration  system

does not replace the filter from the forced

air  heating/cooling  system.  Regular

maintenance of this filter is necessary to

permit the good operation of the forced air

heating/cooling system.

Optional collar

system

installation

Using  kit  no.  CMK500  the  Whole  House

HEPA Filtration system can be converted to

use  8  inch  round  collars  for  application

requiring ducting. The kit includes two, 8

inch round collars, two mounting brackets

for  wall  or  floor  mounting,  installation

guide and fasteners.

2.2

Type of Installation:

Return to Return Integrated System

Installation 

GUIDE

2.1 Planning the Installation

The Whole House HEPA unit is a versatile appliance with multiple installations

configuration. It is recommended to take your time in planning the installation.

Several Installations are illustrated herein’ for Whole House filtration applications:

• Return to return integrated with the forced air 

heating/cooling system.

• Central draw points using dedicated duct system

• Consult the manufacturer for other special applications.

Ducting Flair System

(Hepa Mounted on Duct)

INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL.

Consult your HVAC product manufacturer if the usage of this product will affect the performance of

your forced air heating / cooling system.

Optional Collar System

(Hepa Mounted on Wall)

Return  

Air Plenum

To living 

space

 

 

 

Summary of Contents for H.E.P.A. HP500

Page 1: ...P A FIL TRA TION SYSTEMS Pictured here with the optional collar mount kit For residential installation only MODEL HP500 Installation Operation Maintenance GUIDE H E P A Air Cleaner WHOLE HOUSE HEPA FILTRATION SYSTEM ...

Page 2: ...nty You benefit from a limited 7 year warranty on the motorized impeller and a 5 year limited warranty against manufacturing defects on other components The limited warranty covers normal usage It does not apply to malfunctions or failures as a result ofimproperinstallation abuse mishandling or misapplication or any other circum stances outside the manufacturer s control or consent Warrantyfromthe...

Page 3: ... to find out whether the installation of electrical products requires the services of a certified technician or electrician Model HP500 22 559 mm 13 330mm 17 432 mm 17 432mm 17 432 mm 12 305 mm 11 587 294 5 mm ReturnAir Plenum Installation 12 305 mm 11 587 294 5 mm 22 559 mm Installation requires kit No CMK500 Stage 1 Stage 3 Stage 2 Stage 1 Stage 3 Stage 2 FiltrationStage1 2 PrefilterwithCarbon R...

Page 4: ...is filter is necessary to permit the good operation of the forced air heating cooling system Optional collar system installation Using kit no CMK500 the Whole House HEPAFiltration system can be converted to use 8 inch round collars for application requiring ducting The kit includes two 8 inch round collars two mounting brackets for wall or floor mounting installation guide and fasteners 2 2 Type o...

Page 5: ...ion and circulation throughout the home HEPAsystem must be operated continuously whenever a part or all the system is located in an unconditioned space to avoid condensation in the ductwork below freezing 0 C 32 F StandAlone Basement Installation Ductingwillusuallyconsistofonereturnwith grille from one side of the home and one supply with grille at the opposite end of the home ...

Page 6: ...preparation of the plenum mount system are as followed figure 2 2b One cut permits the clean removal of the insulation piece Step 2 Preparing ducting flairs Remove the door and filters and proceed to cut the insulation as illustrated below figure2 2a Cut the insulation along the inside edge of both inlet and outlet ports to remove the insulation from the port openings Step 1 Preparing return air p...

Page 7: ...ape all around both openings on the back of the unit figure 2 2i Step 2 Continued figure 2 2d figure 2 2e figure 2 2f figure 2 2g Tips to installer InterlockingtheHEPAfiltrationunitwiththe forced air heating cooling system is possi bleusinganauxiliaryrelay Refertopage11 of this guide for example Please consult local authorities to find out whether the installation of electrical products requires t...

Page 8: ... receptacle with 115V It is not rec ommended to connect unit with an extension cord If no receptacle is available please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTERACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is located on the unit s motor plate figure 2 4b Replace door and insert power cord into the recept...

Page 9: ...ilters and speed selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety doorinterlockswitchcutsthepowertothemotors foryoursafety Ifneededthedoorcanberemoved from the cabinet hinges by holding the top part of thedoorwithonehandand gentlytapingonthe bottom edge of the door with the other hand to release the door from its hinges Recommended Operat...

Page 10: ...s only on one speed Possible loose wire inside electrical box contact your local contractor Unit vibrates Check for excessive dust builup or missing balancing weight on the impeller wheel M L Door Interlock Brown N Blue Black 2 5uf 7 5uf G Speed Selection When should I Service my Unit service and accessories Detailed maintenance information is located onthefrontdecalonmotorplate PRE FILTER AND CAR...

Page 11: ...tesimilar Step 1 Turn off electric power to furnace and use a 120V coil SPST N O relay Mount relay to a _ knockout Step 2 Wire the HOT EAC terminal on the furnace s EFC board to one side of the 120V coil on the relay Wire the other side of the 120V coil back to a spare common terminal on the EFC board Step 3 Wire 120V HOT from blower door safety switch use a spade terminal splitter similar to John...

Page 12: ...1 800 982 1840 www premieroneproducts com ...