background image

 

 

P-4 

 

DESCRIPTION 

 
1. Fuel tank 
2. Fuel tank cap 
3. Fuel cock 
4. Air filter cover 
5. Spark plug 
6. Muffler 
7. Choke lever 
 
 
 
 
 
 
 
 
 

15. Oil warning light 
16. AC switch (N.F.B) 
17. Voltmeter 
18. DC socket (optional)  
19. DC circuit breaker (optional)  
20. AC output select SW (optional) 
21. Pilot light  

8. AC socket 
9. Engine switch 
10. Ground (earth) terminal 
11. Oil filter gap 
12. Oil drain plug 
13. Recoil starter 
14. Fuel level gauge 

 

 

                P-5 

 

PRE-OPERATION CHECK 

 

NOTE 

Pre-operation checks should be made each time the generator is used. 
 

CHECK ENGINE FUEL 

z

  Check fuel level at fuel level gauge. 

z

  If fuel level is low, refill with unleaded automotive gasoline. 

z

  Be sure to use fuel filter screen on the fuel filter neck. 

z

  Recommend fuel: Unleaded gasoline. 

z

  Fuel tank capacity: 

 

Model                                              

Full

 

GEN-3300, GEN-3302                        

6.3L 

GEN- 3301                                       

13L 

GEN-3303, GEN-3304, GEN-3305     

25L 

 

NOTE 

z

  Do not refill tank while engine is running or hot. 

z

  Close fuel cock before refueling with fuel. 

z

  Be careful not to admit dust, dirt, water or other foreign objects into fuel. 

z

  Wipe off spilt fuel thoroughly before starting engine. 

z

  Keep open flames away. 

z

 “F”Full,”E”Empty. 

 

CHECK ENGINE OIL 

Before checking or refilling oil, be sure the generator is put on a stable and level surface with engine 
stopped. 

z

  Remove oil filler cap and check the engine oil level. 

z

  If oil level is below the lower level line, refill with suitable oil to upper level line. Do not screw in the oil 

filler cap when checking oil level. 

z

 Change 

oil 

if 

contaminated. 

z

 Oil 

capacity 

z

   

Model                                              

Full

 

GEN-3300, GEN-3302                        

0.37L 

GEN- 3301                                       

0.6L 

GEN-3303, GEN-3304, GEN-3305     

1.1L 

 

z

  Recommend engine oil: 

APL service "SE” or "SF”, if not available, "SD” 
 

GROUND (Earth) 

Make sure to ground (earth) the generator. 
 
 

Reviews: