background image

                                                           

 

2

 

1.0 Specifications 

 
 

        Models 
  Parameter 

CGZL-1/230 CGZL-1/120 CGZL-2/230 CGZL-2/120 

Rated Voltage 

230 V 

120 V 

        230 V 

120 V 

Current,Frequency 

1.25 A

50/60 Hz

2.5 A

50/60 Hz

1.25 A

50/60 Hz  2.5 A

50/60 Hz

Rated Power 

1/4 HP 

1/4 HP 

Weight 

16.4 kg 

36 lb 

15 kg 

33 lb 

Power cord Length 

7.5 m 

24.6 ft   

7.5 m 

24.6 ft 

Air Output(Low 

speed) 

4600 m3/h 

2700 CFM 

4600 m3/h 

2700 CFM 

Air Output(High 

speed) 

5100 m3/h 

3000 CFM 

5100 m3/h 

3000 CFM 

Hour Meter / Draw 

Bar 

Yes/Yes No/No 

SIZE/Width*Height

*Deepth 

640*620*290mm

25.2*24.4*11.4in

640*620*290mm 25.2*24.4*11.4in

 

 

 

 

   

 

           

 

                                 

    Fig. 1                                                                          Fig. 2 

Summary of Contents for CGZL-1/120

Page 1: ...Owner s Manual Axial Blow Dryer Series Read the owner s manual throughly before use Save the Owner s Manual ...

Page 2: ...ons Page 4 4 0 Functions of Operating panel 4 1 Hour Meter Page 4 4 2 Socket and Earth leakage protector Page 4 4 3 Three way Switch Page 4 4 4 12A Overload Protector Page 5 5 0 Parallel Operations Page 5 6 0 Drying Range Page 5 7 0 Maintenance Page 6 8 0 Parts List Page 6 7 9 0 Wiring Diagram Page 7 ...

Page 3: ...0 60 Hz 2 5 A 50 60 Hz Rated Power 1 4 HP 1 4 HP Weight 16 4 kg 36 lb 15 kg 33 lb Power cord Length 7 5 m 24 6 ft 7 5 m 24 6 ft Air Output Low speed 4600 m3 h 2700 CFM 4600 m3 h 2700 CFM Air Output High speed 5100 m3 h 3000 CFM 5100 m3 h 3000 CFM Hour Meter Draw Bar Yes Yes No No SIZE Width Height Deepth 640 620 290mm 25 2 24 4 11 4in 640 620 290mm 25 2 24 4 11 4in Fig 1 Fig 2 ...

Page 4: ...er be serviced or cleaned while it is plugged in Do not plug more than 9 0 amps total into the outlet Do not sit or stand on the machine or use as a shelf or table Check GFCI protection before each use by pushing test button If operating properly reset button will pop out Before leaving an Axial Blow dryer unattended ensure children do not have access to the equipment Do not allow children to play...

Page 5: ...area Moreover it offers time record of all historical operating of the blow dryer 4 2 Socket and Earth leakage protector Fig 3 1 2 CGZL series blow dryers are equipped with sockets through which the blow dryers can be connected one to another The socket is equipped with an earth leakage protector which improves the security of the operator operating the blow dryer under a damp environment The prot...

Page 6: ...blow dryers can be connected through the power socket Fig 3 1 2 on the operating panel The overload protector with current of 12A on the operating panel allows 4 axial blow dryers to use in parallel at the same time Figure 4 Fig 4 6 0 Drying Range The current industry standard requires a blow drier guarantee the straight drying length of 5 meters some industry standards of commercial constructions...

Page 7: ... compressed air or a dust collector to clean dirt on the machine Do not use a high pressure cleaning machine Note any abnormal sound during use Stop the machine for checking in case of any abnormal noise Balance inspection and calibration have been done for blower fans Please take care of the fans during use Never damage them Only professionals allowed to disassemble the blow dryer The removal of ...

Page 8: ...CGE 0013 Rear Grille Ф470 5 2SJ25B01 0003 Motor Grille 6 2SJ25E01 0001 Foot 7 3XCH 0015 Three way Switch B00188 8 3CGK 0001 Overload Protector 12A ZE800 12 9 3CGZ 0007 Socket 10 3CGZ 0006 Hour Meter JY732 03 11 2SJ25Q01 0001 Fan 12 2SJ25A01 0005 Fan Assy 13 3CGD 0002 Hub 1 14 3CGD 0003 Hub 2 15 3CGZ 0005 Draw Bar 9 0 Wiring Diagram ...

Page 9: ...8 Suzhou Premier Electrical Appliance Co Ltd 9 Yangqing Road Suzhou 215001 P R China Service Line 86 512 67255986 Fax 86 512 67259661 Website www premie com cn ...

Reviews: