background image

Installation guide and Owner’s manual

 

Page 4/6

 

20200522 

Septic tanks 

 

Item # 

182065

 

Step 4 – Initial backfill 

 

 

Backfill until you reach the tank shoulder (water level inside the 
septic tank). 

 

It is important that the backfill material be deposited, not dumped. 
Using a bulldozer for this step is not recommended. 

 

Backfill material should be free of organic matter and impermeable 
soil, rock, debris or particles larger than 20 mm (¾") or any object 
that could damage the septic tank.

 

 

Note: It is essential to backfill evenly each side of the septic tank. 

 
 
 

Step 5 – Riser installation 

 

When risers are required, proceed as follows: 

 

Clean the rim of the septic tank access (where the 4 holes are 
located for the lag screws). 

 

Place the rubber seal on the access rim. 

 

Put the the riser in place, aligning the holes in the base of the riser 
with the holes of the access rim. 

 

Tighten the riser in place by using the 4 lag screws and washers 
provided for this purpose.

 

 
 

 

Step 6 – Final backfill of the septic tank 

 

 

When the septic tank is full of water, backfill up to the 
desired height. 

 

The thickness of the backfill over the septic tank must 
not exceed 90 cm (36"). 

 

If necessary, use PSR-060 or PSR-140 risers. 

 

Secure the lids on the septic tank or the risers with the 
supplied lag screws. 

 
 

6. Maintenance 

6.1 Maintenance of the septic tank 

The septic tank should be inspected and emptied regularly. For example, in Québec, the septic tanks must be emptied every two (2) 
years for principal residences and every four (4) years for secondary residences. However, a by-law governing the septic tank emptying 
might have been adopted by a municipality or county, therefore, it is important to consult your local regulations for prescribed 
inspection and emptying frequency. It is also possible that the septic tank has to be emptied according to the scum or sludge level in 
the system. Once the septic tank is emptied and the effluent filter has been cleaned (if required), fill the septic tank with water. 
 
Note: If your home is equipped with a garbage disposal or a sewage pump, we strongly recommend emptying your septic tank more 
frequently. The use of this kind of equipment increases the amount of sludge in the septic tank.  

 

 

 

 

 

p

 

 

 

 

 

Shoulder 

RALLONGE 6 po. OU 14 po.

JOINT DE BUTYLE

4 VIS TIRE-FOND ACIER INOX. 304

Risers PSR-060 150 mm (6") or 

PSR-140 355 mm (14") 

Four (4) X 304 stainless steel lag screws 

with 4 X washers 

Rubber seal 

 

 

90 cm (36") 
maximum 