Ecoflo biofilter – nitrogen reduction unit (ECDn) 

 

Item # 339924 

 

The model and the number of ECDn are determined by the domestic wastewater flow per day. Other factors such as the available 
space, the topography of the lot, as well as the type, permeability and depth of the natural occurring soils could influence model 
selection. 

2.  Ecoflo biofilter – nitrogen reduction unit (ECDn) models

 

There are many different models of ECDn and each model has different characteristics. The letters and numbers associated with the 
ECDn specify the model's characteristics, as presented in the following table with model ECDn-500-P (PACK) as reference: 

 

EC refers to the Ecoflo model 

EC = Ecoflo 100% coco biofilter 

Dn 

Nitrogen removal product with a maximum applicable HLR 575 L/m²-d, 
i.e. of 14.1 gal /ft² 

500 refers to the daily flow capacity 

500 = Capacity of 500 US gallons per day 
600 = Capacity of 600 US gallons per day 
865 = Capacity of 850 US gallons per day 
1000 = Capacity of 1,000 US gallons per day 
1100 = Capacity of 1,100 US gallons per day 

P refers to the material of the shell 

C = Concrete 
P = Plastic (Polyethylene)  

PACK refers to configuration of the primary tank 
and biofilter 

PACK = monobloc configuration, both tight together 
No mention = In line 

 

Therefore, according to this nomenclature, the ECDn-500-P (PACK) model refers to an Ecoflo biofilter, nitrogen reduction version, with 
a daily flow capacity of 500 US gallons, in a polyethylene shell. Both primary tank and biofilter come in a monobloc configuration 
(pack). 
 
For models that doesn’t come into PACK configuration, the recommended hydraulic retention time of the primary/septic tank is a 
minimum of two days at the design daily flow.

 

3.  Installation Diagrams 

NOTE: The installation diagrams below show the ECDn with polyethylene shell-PACK configuration.

 

 

 

 

Summary of Contents for ECOFLO

Page 1: ...OWNER S MANUAL Nitrogen reduction Certified to NSF ANSI standard 40 245 2020...

Page 2: ...reating a rapid mix of the recirculated treated effluent from the ECDn with the organic content of the raw wastewater The recirculation line between the ECDn and the primary tank is simply connected t...

Page 3: ...ft 500 refers to the daily flow capacity 500 Capacity of 500 US gallons per day 600 Capacity of 600 US gallons per day 865 Capacity of 850 US gallons per day 1000 Capacity of 1 000 US gallons per day...

Page 4: ...NEVER discharge content or water from a water softener or other potable water treatment devices backwash a spa or pool in your septic system NEVER discharge wastewater from a recreation vehicle campi...

Page 5: ...ce with this Owner s Manual IMPORTANT Primary tanks can be emptied in several ways that can be classified into two categories complete emptying and selective emptying Complete emptying the most common...

Page 6: ...ust be replaced before the system s treatment capacity and performance begins to deteriorate The filtering media is easily pumped out using a truck adapted to emptying primary tanks The new filtering...

Page 7: ...e air vent as well as other factors unrelated to the ECDn itself can prevent septic gases from dispersing properly and lead to odours If this happens contact Premier Tech s After Sales Service departm...

Page 8: ...ion or act of the Customer or the Customer s Successors including without limiting the generality of the foregoing refusal to allow access to the system for maintenance i Any damage or problem if it i...

Page 9: ...ll be interpreted according to and governed by the provisions of this Warranty and the legislation in effect in the Province of Quebec 11 PRIORITY OF THE CERTIFICATE OF WARRANTY This Warranty supersed...

Page 10: ...______ I hereby declare that the residence serviced by a Premier Tech treatment system located at the above address changed ownership on this date If you are the PREVIOUS owner I have provided the sys...

Reviews: