Premier Mounts FPS-300 Installation Manual Download Page 2

53.38

(HOLD DIM)

 16.00 

 16.00 

 16.00 

 Display Width 

FACTOR 

15.250"

Mounting

Distance

Desired 

Distance

CL

OPTIONAL POWER BOX

OUTLET LOCATION

OPTIONAL POWER BOX

OUTLET LOCATION

THE FIRST SLOTS MUST

ALWAYS HAVE AN ANCHOR 

ON EITHER END IN ANY GIVEN

INSTALLATIONAPPLICATION

ROLLER PLATE

Mounting Distance = Display Width/2 + Desired Distance - 15.25”

WALL STRUCTURE

M8 x 16mm

1/4”

M5 x 10mm

M3 x 8mm

1/4” x 3”

M4 x 5mm

#10

#8 x 1-1/4”

x8

x6

x4

x8

x18

x20

x20

x2

x1

x5

x8

1/8” / 3.25mm

(Wood Only)

7/16”

1

Included components

Required for installation

Note:  Prior to installation start, the installer has the option 
of concealed power and signal boxes mounted flush on 
either the  left or right side upper mounting rail end caps. If 
power and signal cable are to be run externally to the end 
cap, please note provisions have been made to allow for 
external “wire mold” channel to be run into the end caps as 
well.
Unpack all FPS-300 system components and confirm all 
components called out in the supplied parts list are  ac-
counted for.  With all components laid out select the upper 
mounting channel pieces as these will be the first part of the 
system to install.

Note:  If you are using the optional concealed left or right 
side power and signal box sections, install only one side of 
the upper track guide along with the power signal box cover 
that is opposite of where the power and signal is coming 
from.  Power and signal cables must run together from either 
the left or right side for proper operation of the system.

Summary of Contents for FPS-300

Page 1: ... State College Blvd Fullerton CA 92831 USA Warranty Garantie Garantía Garanzia Garantie Waarborg http www mounts com warranty 9535 000 011 0X Rev 2 Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids FPS 300 ...

Page 2: ...either the left or right side upper mounting rail end caps If power and signal cable are to be run externally to the end cap please note provisions have been made to allow for external wire mold channel to be run into the end caps as well Unpack all FPS 300 system components and confirm all components called out in the supplied parts list are ac counted for With all components laid out select the ...

Page 3: ...it to a depth allow ing for full penetration of the mounting screw in the wall to provide a level and firmly attached upper mounting channel Take one 48 in upper channel section A and place it horizontally on the wall and level at the desired height in line with both the predetermined stud locations and with anchoring position in the far right or left slot Mark through the upper channel mounting h...

Page 4: ... with each other and in line at the same starting point as called out in the instructions Once the mounting pilot holes have been drilled take the first 48 in 1219mm section of mounting channel and se cure it level on the wall with the mounting hardware provid ed Once the first upper channel is secure follow the same procedure for the second 48 in 1219mm upper channel Do not overtighten the screws...

Page 5: ... Installazione Guide d Installation Installatie gids FPS 300 Install the power signal boxes to each end Complete all electrical installation at this time Note The upper slider assembly can also be wired using appropriate wire connection With both upper and lower channels level and secure to the wall the main slider assembly can be raised two people recommended with the upper rollers properly seate...

Page 6: ...ll motion of the display on the slider Hard wire the cords to universal electrical box Repeat for signal cable installation Using the spirit level supplied adjust the stand off of the lower roller wheels to provide a level vertical for the slider frame on the wall Loosen the locking screw at the bottom of the roller using a Phillips head screwdriver Install the dome plug and tighten the bottom loc...

Page 7: ...e d Installation Installatie gids FPS 300 Lay the plastic track glide unit with power and signal cable installed within track section fully inside the upper channel receiver section Dress out the power and signal cable at each end using the tie wraps supplied to insure smooth full travel of the slider assembly in both the vertical and horizon tal movements of the system Note The orientation of the...

Page 8: ...ck brackets and hardware sup plied as shown in the visual diagram Secure the power strip to the frame using two 2 M3x8mm screws and two 2 M3 kep nuts Double check all power and signal cables are properly se cured to the system channels as to not cause any pinching of the cables during any movement of the slider system ...

Page 9: ...com www mounts com North America 800 368 9700 International 1 714 632 7100 9535 000 011 0X Rev 2 14 13B Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids FPS 300 Re install the upper channel and end covers securely at this time Use additional tie wraps as needed for proper wire and cable routing ...

Page 10: ...M4 x 5mm M4 x 5mm x8 x8 15B 15A Install the power signal box covers and channel covers ...

Page 11: ...www mounts com North America 800 368 9700 International 1 714 632 7100 9531 060 001 00 Rev 2 16 Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids FPS 300 Refer to the Universal Low Profile Flat Mount for 50 to 80 Flat Panels for instruction on installing the display M8 x 16mm 1 4 x8 x8 ...

Page 12: ...Mounts disclaims any liability for damage to mounts adapters displays projectors other property or personal injury resulting in whole or in part from improper installation modification use or misuse of its products NOTWITHSTANDING ANYTHING TO THE CONTRARY IN THIS WARRANTY THIS WARRANTY IS LIMITED TO FIVE YEARS FROM THE DATE OF PURCHASE IN THE EVENT THAT THE WARRANT ED PRODUCT IS COMMERCIALLY RENTE...