Premier Mounts ECM-3763Q Installation Instructions Manual Download Page 2

ECM-3763Q

Page 2 

Installation Instructions

Contact Premier Mounts with any questions: 
(800) 368-9700
[email protected]

Contents

Warning Statements

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND 
COMPLETELY UNDERSTOOD TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP THESE 
INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.

PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY 
UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, 
DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR 
IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE 
PROPER SAFETY GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

At least two quali

fi

 ed people should perform the assembly procedure. Personal injury and/or property damage can result 

from dropping or mishandling the 

fl

 at panel.

Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are 
no electrical wires in the ceiling. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the ceiling where the mount is to be located. Cutting or drilling into a 
water or gas line may cause severe property damage or personal injury.

This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious 
personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of 
impact.

Weight Capacity

Maximum 

fl

 at panel weight:

360lbs.

THE CEILING STRUCTURE MUST BE CAPABLE OF HOLDING FIVE 
(5) TIMES THE WEIGHT OF THE FLAT PANEL AND MOUNT. IF NOT, 
THEN THE CEILING STRUCTURE MUST BE REINFORCED.

INSTALL THE MOUNT ACCORDING TO  THE INSTRUCTIONS PROVIDED BY PREMIER MOUNTS. PERFORM ALL 
STRUCTURAL REINFORCEMENTS BEFORE ATTACHING THE FLAT PANEL TO THE CEILING MOUNT. USE THE 
APPROPRIATE  LIFTING DEVICE WHEN LIFTING THE FLAT PANEL INTO PLACE.

Installation Tools. ...................................................................................................................................................... 3
Parts List................................................................................................................................................................... 3
Mounting Hardware. ................................................................................................................................................. 4
Features. .................................................................................................................................................................. 5
Installing the Ceiling Mount. ..................................................................................................................................... 6

Selecting the Mounting Hardware. .............................................................................................................. 7
Griplate™ Washer Installation. .................................................................................................................... 8
Nylon Spacer Installation. ............................................................................................................................ 8

Inserting the Hex Head Bolts. ................................................................................................................................... 9
Elliptical Tilt Mount Installation.................................................................................................................................. 9
Attaching the Flat Panel. ........................................................................................................................................ 10
Attaching the Decorative Covers. ........................................................................................................................... 11
Cable Management. ............................................................................................................................................... 11
Tilt Positioning. ....................................................................................................................................................... 12
Technical Speci

fi

 cations. ........................................................................................................................................ 12

Warranty ................................................................................................................................................................. 13
Disclaimer. .............................................................................................................................................................. 13

Summary of Contents for ECM-3763Q

Page 1: ...ne 44 0 24 7664 4105 Fax 44 0 24 7664 4165 3130 East Miraloma Avenue Anaheim CA 92806 USA USA and Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632...

Page 2: ...sure that there are no electrical wires in the ceiling Cutting or drilling into an electrical line may cause serious personal injury Make sure there are no water or natural gas lines inside the ceilin...

Page 3: ...nents Make sure that none of these parts are missing and or damaged before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts 800...

Page 4: ...ad Screw Qty 16 M5 x 50mm Phillips Head Screw Qty 16 M6 x 12mm Phillips Head Screw Qty 32 M6 x 20mm Phillips Head Screw Qty 24 M6 x 30mm Phillips Head Screw Qty 24 M8 x 20mm Phillips Head Screw Qty 24...

Page 5: ...ns Quad Mount Please see Page 6 for installation instructions Decorative Cover Please refer to Page 11 for instructions on how to install the decorative covers Elliptical Tilt Mount Please see Page 9...

Page 6: ...ructure before performing the following steps For more height flexibility use Premier Mounts adjustable height ceiling adapter AST 2446 sold separately The coupler must be threaded onto the NPT thread...

Page 7: ...ve the depth of the threaded insert as shown in Figure 1 Insert the small straw or toothpick into the remaining threaded inserts to compare and verify their depth using the straw or toothpick s 1 8 al...

Page 8: ...points A curved back Any obstruction near the mount point If Yes you must install nylon spacers Remove the mounting brackets Griplate washers and mounting screws from the back of the flat panel Proce...

Page 9: ...ten all four 4 M6 x 12mm hex head bolts Repeat Steps 1 through 5 for mounting the remaining elliptical tilt mounts Proceed to Attaching the Flat Panel section 10mm Wrench M6 x 12mm Hex Head Bolt M6 x...

Page 10: ...nter the mounting bracket arms with the attached flat panel onto the elliptical mounting bar of the ECM 3763Q LJXUH Repeat Steps 1 and 2 for mounting the remaining elliptical tilt mounts Do not releas...

Page 11: ...g hole The decorative covers should easily go over the M6 x 25mm Pan Combo screws Repeat the Attaching Decorative Covers instructions to attach decorative covers to the next flat panel Attaching Decor...

Page 12: ...ards you while the lower hand gently pushes the bottom of the flat panel away from you If additional tilt friction is required tighten the lower nut and lower bolt only to increase the tilt friction A...

Page 13: ...OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the w...

Reviews: