background image

(Tube Complement) 

 

 

 

V1- 12AX7, Clean Channel 
V2- 12AX7, Reverb Send 
V3- 12AT7, Reverb Driver/Mixing amplifier 
V4- 12AX7, Lead Channel 
V5- 12AX7, Phase Inverter 
V6, V7- EL-34(6CA7)/6L6GC, 50 Watt Output 
V8, V9- EL-34(6CA7)/6L6GC, 100 Watt Output 
 
 
Each fine production tube is tested and matched to our exacting specifications.  External bias 
adjustment and test points are located on the chassis near the output tube sockets.  A digital 
voltmeter and small screwdriver are required for bias adjustment.  
 

BIAS ADJUSTMENT PROCEDURE: 

-Power up unit and connect proper speaker load 
-DO NOT have an instrument connected to the input during the biasing procedure! 
-Take unit off standby and allow a few seconds for the circuit to stabilize. 
-Set multi-meter to read DC Volts   
-With meter grounded to chassis and + probe inserted into test point, measure voltage. 
-Using a small flat head screwdriver, insert into Bias pot and turn slowly adjusting Bias level 
 
 
It is recommended to only use exact replacement tubes similar to what is installed at the factory. 
Be careful when deciding to install other types of 6L6, 6V6, or EL-34 based tubes. Not all have the 
same specs and some can’t handle the plate voltage of the amplifier.  
 
 
Below is a limited list of comparable tube types: 

Summary of Contents for Two-Rock Bi-ONYX

Page 1: ...Bi Onyx 5o 1oo Watt OWNERS MANUAL...

Page 2: ...nce with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers plugs and the point where they exit from the apparatus 9 Protect the power cord from be...

Page 3: ...tivated by pulling the Lead Master control 7 Reverb Clean Lead The front panel reverb control is the return or mix control The reverb effect is defeated with this control in the full counter clockwise...

Page 4: ...values The switch must be in the correct position for what tubes are installed in the amp If the switch is in the incorrect position the amplifier will eventually blow the fuse Refer to Fuse Chart fo...

Page 5: ...d from the footswitch A 4 pin XLR cable needs to be used with foot switch and is included in purchase Foot Switch Fuse Chart All Fuses are 3AG Type 250 Volt SLO BLO Export 100 Volt Domestic Fuses Expo...

Page 6: ...unit and connect proper speaker load DO NOT have an instrument connected to the input during the biasing procedure Take unit off standby and allow a few seconds for the circuit to stabilize Set multi...

Page 7: ...gher then 044V as it will cause tube failure Do not set bias higher then recommend levels as it can lead to tube failure or failure within the amplifier amplifiers are brought to you by Premier Builde...

Page 8: ...ning solvents Wipe exterior with a clean dry cloth only Refer servicing to a qualified service technician This is a product of Premier Builders Guild 619 MARTIN AVENUE SUITE 6 ROHNERT PARK CA 94928 70...

Page 9: ......

Reviews: