TECHNICAL SPECIFICATION 

 

Dimensions (wall mounting): 

 

 

530×300×58 mm 

Dimensions (floor standing): 

 

 

530×300×150 mm 

Weight: 

 

 

 

 

2.2 kg 

Power supply: 

 

 

 

230 V AC 

Power consumption:  

 

 

600 W  

Operating current: 

 

 

 

2.6 A 

 

SERVICE WARRANTY 

 

 

Prem-i-Air  guarantees  the  product  free  from  defects  in  materials  and 
workmanship for a period of twelve months. 

 

Should  this  appliance  be  operated  under  conditions  other  than  those 
recommended, at voltages other than the voltage indicated on the appliance, 
or  any attempts made to service or modify the appliance, then the warranty 
will be rendered void. 

 

The  product  you  buy  may  sometimes  differ  slightly  from  illustrations.  This 
warranty is in addition to, and does not affect, your statutory rights. 

 

Our guarantee is administered by our retailers. 

 

If  your  product  arrives  damaged,  you  must  contact  the  retailer  from  whom 
you bought it. The retailer's contact details will be on the invoice that arrived 
with  the  product,  or  on  the  e-mail  you  received  when  you  placed  the  order. 
Do not contact Prem-i-air, only your retailer can arrange a replacement. 

 

If your product fails within the guarantee period, firstly read the "fault finding" 
section  of  this  manual,  because  temperature  and  weather  conditions  can 
affect  the  performance  of  certain  products.  If  the  product   needs  to  be 
repaired or replaced, you must contact the retailer from whom you bought it. 

 

The  retailer's  contact  details  will  be  on  the  invoice  that  arrived  with  the 
product, or on the e-mail you received when you placed the order. 

 

If  you  have  just  received  your  product  and  require  techical  help  in  using  it, 
please call our Help Desk on (0845) 459 4816 

 

If  you  have  any  other  technical  queires  about  the  product,  please  call  our 
Help Desk on (0845) 459 4816 

 

Prem-i-Air Appliances Ltd., 

Lancots Lane, Sutton, 

St. Helens, Merseyside. 

WA9 3EX 

website: 

www.prem-i-air.com

 

 

 

Summary of Contents for EH1524

Page 1: ...Page 1 EH1524 600 W Panel Heater Radiateur Convecteur 600 W ...

Page 2: ...o the diagram opposite draw two horizontal lines on the wall 258 mm 10 apart the lower line more than 50 mm 2 from the floor On the upper line drill holes 183 mm 7 from the centre line using a 6 mm masonry bit and insert a wall plug On the lower line drill holes 188 mm 7 from the centre line using a 6 mm masonry bit and insert a wall plug Fix the two hook brackets to the upper holes using the 30 m...

Page 3: ...Page 3 ...

Page 4: ...perate unless the plastic feet correctly attached Do not place on soft surfaces Do not cover This symbol shown on the casing of the heater means that the heater should not be covered For indoor use only Do not use in bathrooms or in wet or damp locations Do not use in the immediate surroundings of a bath a shower or a swimming pool Do not place the mains lead beneath a carpet or rug Do not use the...

Page 5: ...e that the switch in the centre of the timer is in the correct position Do not touch the air output grille when the heater is in operation because it will be hot and may cause burns Unplug the heater from the mains when not in use USING THE TIMER When the timer switch is in this position the heater will be permanently OFF Use this position in the summer when a permanently installed heater is not r...

Page 6: ...clockwise The heater will then operate at maximum output When the desired temperature is reached rotate the temperature control anticlockwise until a click is heard The heater will then switch on and off to keep the room at the desired temperature If the temperature control is rotated fully anticlockwise it will operate as a frost stat and switch the heater on if the temperature drops below 4 C pr...

Page 7: ... Make sure that the cord grip is positioned correctly over the outer sheath of the cable and it fully tightened FAULT FINDING The EH1524 has an overheat protection switch which disconnects the power if the element gets too hot The usual reason for this is because the air flow has been obstructed or the grilles have been blocked If the heater ceases to operate leave it for 20 minutes to cool down t...

Page 8: ...e retailer from whom you bought it The retailer s contact details will be on the invoice that arrived with the product or on the e mail you received when you placed the order Do not contact Prem i air only your retailer can arrange a replacement If your product fails within the guarantee period firstly read the fault finding section of this manual because temperature and weather conditions can aff...

Page 9: ...ed Pour une installation murale En vous référant au diagramme fourni tracez deux lignes horizontales distantes de 258 mm sur le mur la ligne du bas doit être tracée à plus de 50 mm du sol Sur la ligne du haut percez de chaque côté des trous à 183 mm de l axe central en utilisant un foret à maçonnerie de 6 mm et insérez une cheville murale Sur la ligne du bas percez de chaque côté des trous à 188 m...

Page 10: ...Page 10 ...

Page 11: ...face molle ou instable Ne pas couvrir Ce symbole figurant sur le radiateur indique que le radiateur ne doit pas être couvert Pour utilisation à l intérieur uniquement Ne pas utilisez dans une salle de bains ni dans des pièces humides ou mouillées Ne pas utiliser dans alentours immédiats d une salle de bains d une cabine de douche ou d une piscine Ne placez pas le cordon d alimentation sous un tapi...

Page 12: ...diateur est en fonctionnement car celle ci est chaude et pourrait vous brûler Débranchez l appareil quand vous ne l utilisez pas UTILISATION DU THERMOSTAT Le thermostat peut être utilisé pour réguler la température de la pièce Allumez le radiateur et tournez le bouton du thermostat complètement vers la droite Le radiateur fonctionnera alors à pleine puissance Quand la température désirée est attei...

Page 13: ...temps ou tournez le segment intérieur vers le centre du cadran si le radiateur doit être éteint pendant cette période de temps Tournez la molette dans le sens des aiguilles d une montre jusqu à la pointe de la flèche située à droite du cadran Pour utiliser le radiateur en mode temporisé le radiateur doit être branché en permanence S il est débranché l horloge s arrêtera Pour utiliser le radiateur ...

Page 14: ...magé il doit être remplacé par un technicien qualifié Si la prise doit être changée procédez comme suit Connectez le fil marron sur le bornier libellé L Connectez le fil bleu sur le bornier connecté N Connectez le fil vert jaune sur le bornier libellé E ou portant le symbole terre Vérifiez que le serre câble est positionné correctement sur la gaine extérieure du câble et bien serré DEFAUTS DE FONC...

Page 15: ...ils Dans le cas contraire renseignez vous après de votre mairie Quand vous remplacez l appareil existant par un appareil neuf similaire votre revendeur peut se charger du recyclage de l ancien appareil CARACTERISTIQUES TECHNIQUES Dimensions installation murale 530 300 50 mm Dimensions posé au sol 530 300 150 mm Poids 2 2 kg Alimentation 230 V CA Consommation 600 W Courant de Fonctionnement 2 6 A ...

Page 16: ...e mail que vous avez reçu quand vous avez passé votre commande Ne contactez pas Prem i air seul votre revendeur peut s occuper du remplacement du produit Si votre appareil tombe en panne pendant la période de garantie veuillez tout d abord consulter la section défauts de fonctionnement de votre notice d utilisation car la température et les conditions climatiques peuvent affecter la performance de...

Reviews: