OPERATING COSTS 

At time of going to press, the average cost of electricity is £0.13 per unit (kilowatt-
hour). The amount you are being charged will be shown on your electricity bill. 
At this cost, the EH1462 will cost £0.13 per hour to run on the "low heat " setting, 
and £0.26 per hour to run on the "high heat". 

MAINTENANCE 

Before cleaning, turn the heater off, and disconnect from the mains supply. The 
heater may then be cleaned using a damp cloth with a drop of washing-up liquid 
to  remove  any  dust  or  dirt  from  the  case.  Do  no  use  stronger  detergents  or 
solvents as these may damage the paint finish. 
Using a dry 1" (25 mm) paint-brush, remove any dust from the grilles. 

 

If  the  mains  lead  is  damaged,  it  must  be  replaced  by  the  manufacturer  or 
and  authorised  service  centre.  If  the  mains  plug  needs  to  be  replaced, 
proceed as follows: 

 

Connect  the  brown  wire  to  the 
terminal labelled "L". 

 

Connect the blue wire to the terminal 
labelled "N". 

 

Connect the green/yellow wire to the 
terminal  labelled  with  the  earth 
symbol or "E".  

 

Make  sure  that  the  cord-grip  is 
positioned  correctly  (over  the  outer 
sheath  of  the  cable)  and  is  fully 
tightened. 

DISPOSAL AND RECYCLING 

You must not dispose of this appliance with domestic household waste.  
Most local authorities have specific collection system for appliances and disposal 
is free of charge to the end-user. 
When  replacing  an  existing  appliance  with  a  similar  new  appliance  your retailer 
may take the old appliance for disposal. 

TECHNICAL SPECIFICATION 

Dimensions: 

 

 

600x240x200 mm 

Weight: 

 

 

 

2.8 kg 

Power supply: 

 

 

230 V 

Power consumption:  

 

2300 W 

Operating current: 

 

 

10 A 

IP Rating:  

 

 

IP34 

 

Summary of Contents for EH1462

Page 1: ...1 2837 Ver 1 04 14 EH1462 2 3 kW PATIO HEATER CHAUFFAGE DE PATIO 2 3kW ...

Page 2: ... than 1500 mm 5 from the floor Mark a centre line vertically down across both lines fig 1 On the upper line drill holes 130 mm approx 5 from the centre line on each side using a 6 mm masonry bit and insert a wall plug On the lower line repeat the actions marking and drilling 2 holes and inserting the correct wall plugs fig 2 Insert screws into the lower two holes and tighten to 3 mm from the wall ...

Page 3: ...3 2837 Ver 1 04 14 3 4 5 6 7 8 ...

Page 4: ... connected via a Residual Current Device RCD rated at 30 mA or less The heater must be installed where it cannot be touched whilst in a bath or shower This heater must not be connected to a timer or other type or programmable switch a fire hazard exists if the heater is covered when the timer switches it on The fireguard of this appliance is intended to prevent direct access to the heating element...

Page 5: ...ns off the integrated light H Front Panel Only Turns on and off the 2 heating bars The unit has 3 power modes and off bottom tube 1150 W top tube 1150 W and both tubes 2300 W Press the button gain to turn them all off H1 H2 Remote Control Only independently turns off and on the two heating tubes H1 Bottom H2 Top Eco Panel Remote Control this puts the unit into Eco mode in this position the unit s ...

Page 6: ...d it must be replaced by the manufacturer or and authorised service centre If the mains plug needs to be replaced proceed as follows Connect the brown wire to the terminal labelled L Connect the blue wire to the terminal labelled N Connect the green yellow wire to the terminal labelled with the earth symbol or E Make sure that the cord grip is positioned correctly over the outer sheath of the cabl...

Page 7: ...izontales sur le mur distantes l une de l autre de 90mm la ligne du bas devant être tracée à plus de 1500mm du sol Tracez une ligne centrale verticale coupant ces deux traits Fig 1 Sur la ligne du haut percez des trous de chaque côté à 130mm du trait central en utilisant un foret à maçonnerie puis insérez une cheville murale Sur la ligne du bas répétez la même action fig 2 Insérez des vis dans les...

Page 8: ...8 2837 Ver 1 04 14 3 4 5 6 7 8 ...

Page 9: ...it provoquer une surchauffe ou un choc électrique et endommager le radiateur S il est utilisé à l extérieur le radiateur doit être branché via un dispositif de courant résiduel calibré à 30mA ou moins Le radiateur doit être installé à un endroit afin qu il ne puisse pas être touché depuis une baignoire ou une douche Le radiateur ne doit pas être connecté à un programmateur ou un commutateur progra...

Page 10: ...niquement Allume et éteint les 2 tubes chauffants L appareil peut fonctionner selon 3 modes différents le tube du bas 1150W uniquement le tube du haut uniquement 1150W ou les 2 tubes 2300W Appuyez de nouveau sur le bouton pour tous les éteindre o H1 H2 sur la télécommande uniquement allume et éteint indépendamment les deux tubes chauffants H1 pour le tube du bas et H2 pour le tube du haut o Eco Fa...

Page 11: ...astique A l aide d un pinceau sec 25 mm enlevez la poussière des grilles Si le cordon d alimentation est endommagé il doit être remplacé par un électricien confirmé Procédez comme suit Connectez le câble marron sur le bornier libellé L Connectez le câble bleu sur le bornier libellé N Connectez le câble vert jaune sur le bornier libellé E ou portant le symbole terre Vérifiez que le serre câble est ...

Page 12: ...Appliances Ltd Lancots Lane Sutton St Helens Merseyside WA9 3EX website www prem i air com GARANTIE Prem I Air garantit ce produit contre tout défaut de fabrication ou de matériaux pendant douze mois Si ce radiateur est utilisé dans des conditions autres que celles recommandées dans cette notice à des tensions autres que celles indiquées sur l appareil la garantie est annulée De même toute tentati...

Reviews: