OPERATING COSTS

At time of going to press, the average cost of electricity is
£0.11 per unit (kilowatt-hour). The amount you are being
charged will be shown on your electricity bill.
At this cost, the EH1226 will cost £0.11 per hour to run on the
"low heat " setting, and £0.22 per hour to run on the "high
heat".

MAINTENANCE

Before cleaning, turn the heater off, and disconnect from the
mains supply. The heater may then be cleaned using a damp
cloth with a drop of washing-up liquid to remove any dust or
dirt from the case. Do no use stronger detergents or solvents
as these may damage the paint finish.
Using a dry 1" (25 mm) paint-brush, remove any dust from
the grilles.
If the mains lead is damaged, it must be replaced by the
manufacturer or and authorised service centre. If the mains
plug needs to be replaced, proceed as follows:

 Connect the brown wire to the

terminal labelled "L".

 Connect the blue wire to the

terminal labelled "N".

 Connect the green/yellow wire

to the terminal labelled with the
earth symbol or "E". 

 Make sure that the cord-grip is

positioned correctly (over the
outer sheath of the cable) and it
fully tightened.

 Page 6

Summary of Contents for EH1226

Page 1: ...EH1226 2 kW Patio Heater 2 Heat settings Pull cord switch Wall mounting Suitable for outdoor use Adjustable angle Page 1 ...

Page 2: ...mm masonry bit and insert a wall plug Insert screws into the upper two holes and almost fully tighten Hang the heater on the upper screws using the keyhole slots on the back Insert a screw through the hole in the heater just below the power display window This screw will fit into the lower hole Fully tighten the screw and push the rubber plug supplied into the hole to protect from water ingress PA...

Page 3: ...ry 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiring must be inspected at least once every 5 years It is recommended that all building be fitted with smoke alarms it is mandatory for new buildings DRILLING DIMENSIONS FOR WALL MOUNTING 98 00mm Page 3 ...

Page 4: ...e Do not place the mains lead beneath a carpet or rug Do not use the heater in locations where paint petrol or other flammable liquids are used or stored Do no insert any object into the heater through the grilles This may damage the heater or result in overheating or electric shock If used outdoors the heater must be connected via a Residual Current Device RCD rated at 30 mA or less Do not use th...

Page 5: ...l the cord operated switch to select the required operation Figure 1 displayed Low Heat 1000 W Figure 2 displayed High Heat 2000 W Do not touch the grille when the heater is in operation because it will be hot and may cause burns Unplug the heater from the mains when not in use To adjust the angle switch off the heater and allow it to cool for 15 minutes Slacken the pivot screw and adjust the refl...

Page 6: ...g up liquid to remove any dust or dirt from the case Do no use stronger detergents or solvents as these may damage the paint finish Using a dry 1 25 mm paint brush remove any dust from the grilles If the mains lead is damaged it must be replaced by the manufacturer or and authorised service centre If the mains plug needs to be replaced proceed as follows Connect the brown wire to the terminal labe...

Page 7: ... system for appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal TECHNICAL SPECIFICATION Dimensions wall mounting 190 480 400 mm Weight 2 kg Power supply 230 V Power consumption 2000 W Operating current 8 7 A Page 7 ...

Page 8: ...d on the appliance or any attempts made to service or modify the appliance then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your statutory rights If you have any problems with this product please call our Help Desk on 0845 459 4816 Prem i Air Appliances Ltd Lancots Lane Sutton St Helens ...

Reviews: