background image

FAULT-FINDING

The EH1264 has an overheat protection switch, which
disconnects the power if the element gets too hot. The usual
reason for this is because the air-flow has been obstructed,
or the grilles have been blocked. If the heater ceases to
operate, leave it for 20 minutes to cool down, then check that
the grilles are not being obstructed.
Switch back on, and check that the unit is operating normally.
If not, contact an authorised service agent for repair.

DISPOSAL AND RECYCLING

You must not dispose of this appliance with domestic
household waste. 

Most local authorities have specific collection system for
appliances and disposal is free of charge to the end-user.
When replacing an existing appliance with a similar new
appliance your retailer may take the old appliance for
disposal.

TECHNICAL SPECIFICATION

Dimensions (wall mounting):

468×690×136mm

Dimensions (floor standing):

468×760×260mm

Weight:

5kg

Power supply:

230V AC

Power consumption:

1000W

Operating current:

4.3A

 Page 7

Summary of Contents for EH1264

Page 1: ...EH1264 1kW Convector Heater 2 Heat settings Adjustable thermostat Free standing or wall mounting Convenient built in carrying handle Safety overload cut out 2 year guarantee Page 1 ...

Page 2: ...eater Referring to the diagram opposite draw two horizontal lines on the wall 431mm 17 apart the lower line more than 50mm 2 from the floor On the upper line drill holes 110mm 4 from the centre line using a 6mm masonry bit and insert a wall plug Insert a screw into the hole and almost fully tighten On the lower line drill a hole on the centre line using a 6mm masonry bit and insert a wall plug Han...

Page 3: ...DRILLING DIMENSIONS FOR WALL MOUNTING 105mm 105mm 431mm Page 3 ...

Page 4: ... are at least 900mm 3 from the top of the heater Leave a gap of at least 50mm 2 at the sides of the heater If used free standing do not operate unless the feet are correctly attached Do not place on soft surfaces Do not cover This symbol shown on the casing of the heater means that the heater should not be covered Do not use outdoors Do not locate the heater immediately below a socket outlet Do no...

Page 5: ...se USING THE THERMOSTAT The thermostat can be use to regulate the room temperature Turn both switches on high heat and rotate the temperature control fully clockwise The heater will then operate at maximum output When the desired temperature is reached rotate the temperature control anticlockwise until a click is heard The heater will then switch on and off to keep the room at the desired temperat...

Page 6: ... mains supply The heater may then be cleaned using a damp cloth with a drop of washing up liquid to remove any dust or dirt from the case Do no use stronger detergents or solvents as these may damage the paint finish Using a dry 1 25mm paint brush remove any dust from the grilles If the mains lead is damaged it must be replaced by the manufacturer or and authorised service centre If the mains plug...

Page 7: ...rating normally If not contact an authorised service agent for repair DISPOSAL AND RECYCLING You must not dispose of this appliance with domestic household waste Most local authorities have specific collection system for appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal T...

Page 8: ...hould this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your statutory rights If you have any problems with this ...

Reviews: