2  

Assembly Instructions, Power Rail P6 (Version 2, Rev A)

About the product

The Power Rail top-clamping PV module 

mounting system is engineered to reduce in-

stallation costs and provide maximum strength 

for parallel-to-roof or tilt up mounting applica-

tions.
Designed with the professional PV solar in-

staller in mind, the top-clamping rails utilize a 

single tool with a revolutionary RAD™ Fasten-

er for faster bolt placement. The unique shape 

of the RAD provides an anti-rotation feature, 

locking the bolt in the proper orientation when 

installed. The high strength rigid rails also in-

clude an integral wiring channel for securing 

cables  and  providing  a  professional  finish. 

The Power Rail Mounting System features 

the industry’s broadest selection of mounting 

supports, designed for secure and water tight 

attachments to any roof style.

For recommendations on a specific installa

-

tion, please:
Visit www.DPWSolar.com and select the Pow-

er Rail Configuration Design Tool.

Contact us by Phone: 800-260-3792
Send an Email request: [email protected]

About these instructions:

•  They do not include any information on the 

selection or installation of attaching hard-

ware to be mounted to the roof substrate. 

For information on compatible attaching 

hardware, see our publication titled “Pow-

er Rail Design Guidelines”.

•  They begin after all roof mounted attach-

ing hardware has been installed and se-

cured to the roof substrate. 

•  They show the Power Rail Mounting Sys-

tem being installed on the “Power Rail PV 

Flash” roof attachment system.

Power Rail 

TM

 P6

WARNING

Follow the pro-

cedures and 

precautions in 

these instructions 

carefully.

•  These instructions are intended to be used 

by  individuals  with  sufficient  technical  skills 

for the task. Knowledge and use of hand 

tools, measuring devices and torque values 

is also required.

•  These instructions include various precau-

tions in the forms of Notes, Cautions, and 

Warnings. These are to assist in the as-

sembly process and/or to draw attention to 

the fact that certain assembly steps may be 

dangerous and could cause serious personal 

injury and/or damage to components. Follow-

ing the step-by-step procedures and these 

precautions should minimize the risk of any 

personal injury or damage to components 

while making the installation not only safe but 

an efficient process.

Periodic Inspection

Periodic re-inspection is a recommended system 

maintenance procedure to check for any loose 

components and any corrosion. If any loose com-

ponents and any corrosion is found, the affected 

components are required to be replaced immedi-

ately, with the original mounting system manufac-

turer’s component parts.

Required Tools

1/2 inch wrench or socket for 5/16 inch  

module clamp hardware

Torque wrench

Ratchet wrench

Ratchet extension bar

Tape Measure

Square 

Summary of Contents for POWER RAIL P6

Page 1: ...Assembly Instructions step by step assembly and installation Assembly Instructions Version 2 Rev A SP3411 1 PCN 020317 1 POWER RAILTM P6...

Page 2: ...clamps have integrated grounding and have been tested to UL 2703 See Module Compatibility List for list of approved modules Module Orientation Portrait or Landscape Power RailTM P6 Ratings Fire Class...

Page 3: ...idelines They begin after all roof mounted attach ing hardware has been installed and se cured to the roof substrate They show the Power Rail Mounting Sys tem being installed on the Power Rail PV Flas...

Page 4: ...l P6 Main Components There are five main components and attaching hardware RAD End Clamp L Foot AMPTM Clamp Bonding Clamp P6 Power Rail Splice Plate two hole Splice Plate four hole Factory Assembled A...

Page 5: ...Foot 5 16 x 3 4 turn bolt flange nut Refer to Power Rail Design Guidelines 4 AMP Clamp 5 16 x RAD bolt flange nut 2 per 3 8 gap between modules 5 RAD End C l amp 5 16 x RAD bolt flange nut 4 per Rail...

Page 6: ...ompression block and secure with 5 16 Hex Nut and Flat Washer Torque to 14 16 ft lbs CAUTION NOTE NOTE Cantilever and span dimensions are a design spec ification Consult the design manual to match the...

Page 7: ...dules Splice Plates come in two configurations 2 hole or 4 hole above is a 4 hole Insert 5 16 x 3 4 Turn Bolts into Power Rail and rotate 90 degrees to lock Turn Bolts in place Align Splice Plate with...

Page 8: ...rted into the Power Rail and positioned between adjacent Modules Insert the 5 16 RAD Bolt into Power Rail and rotate 4 Install the Modules cont 90 degrees clockwise to lock the RAD Bolt within the Pow...

Page 9: ...8 Assembly Instructions Power Rail P6 Version 2 Rev A Grounding Bonding Path...

Page 10: ...C260PE REC265PE REC270PE Silfab 38 mm SLA260M SLA265M SLA270M SLA275M SLA280M SLA285M SLA290M SLA295M SLA300M Solar World 31 mm SW280 31mm 33 mm SW280 285 290 295 300 33 mm SW 320 XL 33mm FR SW 325 XL...

Page 11: ...Web Site www preformed com E mail inquiries preformed com Albuquerque Office 1700 Louisiana Blvd Suite 130 Albuquerque NM 87110 Telephone 800 260 3792 Fax 505 889 3548 Web Site www DPWSolar com E mai...

Reviews: