background image

 

 

SAFETY SUMMARY 

The  following  general  safety  precautions  must  be  observed  during  all  phases  of 

operation,  service,  and  repair  of  this  product.  Failure  to  comply  with  these 

precautions or specific WARNINGS given elsewhere in this manual will violate safety 

standards of design, manufacture, and intended use of the product.   

Preen  assumes  no  liability  for  the  customer‘s  failure  to  comply  with  these 

requirements, causing malfunction or damage on the product, personal injury, death 

or any loss of, or damage to, property. 

 

1) BEFORE APPLYING POWER   

 

Verify that the product is set to match with the power line input.   

 

Before relocating the product or reconnecting any cable, ensure the power line 

input is cut off and the product has been shut down for 20 minutes. 

 

2) PROTECTIVE GROUNDING   

Make  sure  to  connect  the  product  to  the  protective  ground  to  prevent  an  electric 

shock before turning on the power.   

 

3) NECESSITY OF PROTECTIVE GROUNDING   

Never  cut  off  the  internal  or  external  protective  grounding  wire,  or  disconnect  the 

wiring of protective grounding terminal. Doing so will cause a potential shock hazard 

that may bring injury to a person.   

.

 

4) OPERATING ENVIRONMENT 

 

Do not operate the product in an area with poor ventilation.   

 

Do not operate the product in the presence of flammable gases or fumes.   

 

Do not block the cooling fan opening.   

 

Do not push objects of any kind through the opening, or spill liquid of any kind 

in the product. 

 

5) DO NOT REMOVE THE COVER OF THE PRODUCT   

Hazardous  voltages  may  be  present  when  covers  are  removed.

 

Component 

replacement and internal adjustment can be done only by qualified service personnel.

Summary of Contents for AFV-P-T620 Series

Page 1: ...ries 620V Voltage Transform Unit for AFV P Series User Manual AC Power Corp Preen V 1 4 EN The information in this document is subject to change without notice Copyright by AC Power Corp Preen All rig...

Page 2: ...ess for a particular purpose AC Power Corp shall not be held liable for errors contained herein or direct indirect special incidental or consequential damages in connection with the furnishing perform...

Page 3: ...repairs will be billed at cost Preen assumes no responsibility for its product being used in a hazardous or dangerous manner either alone or in conjunction with other equipment High voltage used in so...

Page 4: ...e product has been shut down for 20 minutes 2 PROTECTIVE GROUNDING Make sure to connect the product to the protective ground to prevent an electric shock before turning on the power 3 NECESSITY OF PRO...

Page 5: ...onnected to the output are touched when the power is applied In the event that there is fire occurring in the vicinity please use dry powder extinguishers The use of liquid extinguishers may give rise...

Page 6: ...odel 45 500Hz AFV P A model 45 1000Hz Frequency Resolution 0 1Hz at 100Hz 1Hz at 100Hz Frequency Stability 0 01 Max Current RMS 1 25A 2 5A 5A 10A Max Current Peak 5A 10A 20A 40A Power W 500W 1000W 200...

Page 7: ...Peak Current Accuracy 2 of reading 5 Counts at 500Hz 2 of reading 10 Counts at 500Hz Power Range Hi 100 1200W Lo 0 0 120 0W Hi 200 2400W Lo 0 0 240 0W Hi 0 4800W Power Resolution Hi 1W Lo 0 1W Hi 1W P...

Page 8: ...han or equal to the maximum rated current of the product Figure 1 Referring to Figure 1 perform the following steps 1 Remove the safety covers of the input and output terminal from the rear panel of A...

Page 9: ...tion After installation ensure AFV P s input is well connected Turn on AFV P and perform the following steps on its touch screen to setup 1 After the power on procedure press MENU at the main page see...

Page 10: ...Series 620V Voltage Transform Unit 3 Press SYSTEM and press the icon to move to the last page of the SYSTEM subpage see Figure 4 Figure 4 4 Switch the icon status of AC 620V from OFF to ON see Figure...

Page 11: ...t ON the VOLTAGE SENSE go to MENU SETTING TESTING will automatically change from INT to EXT However when AC 620V item is switched from ON to OFF the item of VOLTAGE SENSE will still remain EXT So if t...