Predator 69672 Owner'S Manual Download Page 8

      Page 8

For Generator technical questions, please call 1-888-866-5797.

For Engine technical questions, please call 1-800-520-0882.

Item  69672  69674        

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Initial Tool Set Up/Assembly

Read the ENTIRE IMPORTANT 

SAFETY INFORMATION section at the 

beginning of this manual including 

all text under subheadings therein 

before set up or use of this product.

Note:

 For additional information regarding the 

parts listed in the following pages, refer to the 

Assembly Diagram near the end of this manual.

TO PREVENT SERIOUS INJURY: 

Operate only with proper spark arrestor installed.

Operation of this equipment may create sparks that 

can start fires around dry vegetation. 

A spark arrestor may be required. 

The operator should contact local fire 

agencies for laws or regulations relating 

to fire prevention requirements.

CAUTION:

 This generator is not intended to power 

sensitive electronic equipment without the addition of an 

appropriate line conditioner and surge protector (both not 

included).  

Sensitive electronic equipment includes, 

but is not limited to, audio/video equipment, some 

television sets, computers, and printers. 

Sensitive 

electronic equipment should be operated on approved 

inverter type generators or pure sine wave generators.

Note:

 Wheel Kit, item # 68531 (sold separately) 

can be used with this generator.

Grounding

The Generator must be properly grounded before 

use. Have the unit grounded by a qualified 

electrician if you are not qualified to do so.

To ground the Generator, connect a #6 AWG 

grounding wire (not included) from the Grounding 

Terminal on the Control Panel to a grounding rod 

(not included) that has been driven at least 24 

inches deep into the earth. The grounding rod must 

be an earth‑driven copper or brass rod (electrode) 

which can adequately ground the Generator.

Operating Instructions

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this 

manual including all text under subheadings therein before set up or use of this product.

Inspect tool before use, looking for damaged, loose, and missing parts.  

If any problems are found, do not use tool until repaired.

Generator Pre-Start Checks

Inspect engine and equipment, looking for damaged, loose, and missing parts before set up 

and starting.  If any problems are found, do not use equipment until fixed properly.

Checking and Filling Engine Oil

CAUTION!

  

Your Warranty is VOID if the engine’s crankcase is not properly filled with oil before 

each use.  Before each use, check the oil level.  Do not run the engine with low or no engine oil.  

Running the engine with no or low engine oil WILL permanently damage the engine.

1.  Make sure the engine is stopped and is level.

2.  Close the Fuel Valve.

3.  Clean the top of the Dipstick and the area around it.  Remove the Dipstick by 

threading it counterclockwise, and wipe it off with a clean lint free rag.

Summary of Contents for 69672

Page 1: ......

Page 2: ...wed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable ma...

Page 3: ...ially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spil...

Page 4: ...ded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doin...

Page 5: ...speed 6 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadab...

Page 6: ...t 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit sold separately Item 69674 The emission control system for this Generator s Eng...

Page 7: ...ent only to the Receptacle 120 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit...

Page 8: ...enerator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do so To ground the Generator connect a 6 AWG ground...

Page 9: ...nd or causing damage 4 Then replace the Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs i...

Page 10: ...gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do...

Page 11: ...rge batteries without a proper charge controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads...

Page 12: ...atts needed To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use...

Page 13: ...P Stopping the Engine in an Emergency 1 To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the...

Page 14: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment...

Page 15: ...ine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt the crankcase slightly to help dr...

Page 16: ...ally enter the engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL WARNING TO PREVENT SERIOUS INJURY FROM FIRE Drain the fuel tank in a well ventilated area...

Page 17: ...oke to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1...

Page 18: ...ine to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fue...

Page 19: ...r Carburetor 1 55 Packing Insulator 1 56 Carburetor Assy 1 57 Packing Air Cleaner 1 58 Nut Flange 2 59 Air Cleaner Assy 1 60 Element Air Cleaner Assy 1 61 Clip Harness 1 62 Grommet Cord 1 63 Holder St...

Page 20: ...ipe Clip 2 109 Bolt Flange M6 25 4 110 Washer 6 25 2 4 111 Collar Tank Cushion 4 112 Rubber Fuel Cushion 4 113 Rubber Fuel Tank Mounting 2 114 Pipe 1 115 Pipe 1 116 Carbon 1 117 Bracket Carbon 1 118 G...

Page 21: ...Page 21 For Generator technical questions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram...

Page 22: ...tions please call 1 888 866 5797 For Engine technical questions please call 1 800 520 0882 Item 69672 69674 SAFETY OPERATION MAINTENANCE SETUP Assembly Diagram cont Note Parts 114 117 and 141 143 are...

Page 23: ...ol system on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as...

Page 24: ...rts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommenda...

Reviews: