4. Make sure that the clip is properly stowed and not wrapped around the handle-
bars.
Heart Rate Monitor Test
Verify the Handheld Heart Rate function.
1. Access the Hardware Validation Test (51765761) and do the
Heart Rate Test
.
Return to service
1. Verify that there are no new error codes.
2. Switch the power OFF.
3. Make sure that the machine is setting level and stable.
4. Make sure that any external power cords or interface cables are properly routed,
connected, and safe from being damaged.
5. On successful completion of all verification tests, return to service.
R20 Operation Verification Test
R20 Operation Verificaiton Test
The Operation Verification Test applies to equipment configured with the R20 console. Com-
plete each test to verify the equipment operation.
Error Code Verification Test
Verify that there are no current active logged error codes:
1. Access the
Error Log
and record any current active logged error codes:
l
From the
Home
screen press and hold the
PAUSE
key for 5-6 seconds.
o
If there are no errors, the
STUCK KEY
message will scroll across
the display.
o
If there are any logged errors, the error code will be displayed.
Make note of all the error codes and associated odometer and
hour meter readings. This information will help you determine the
relevance of the error.
Use the left and right arrow keys to scroll through multiple error
codes.
2. Resolve any current active logged error code issues.
3. Press
WORKOUTS
or
PAUSE
to exit the Error Log.
4. Verify that all active error codes have been cleared from the
Error Log
.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 20
3 Operation Verification
R20 Operation Verification Test