Setting Up the Console
31
The following table contains a list of events detectable by the
software.
Table 5. Event log numbers and descriptions
Event
Number
Description of Event
00
Upper PCA memory location event
02
RAM location event
03
EEPROM checksum event
05
Depressed key at power up
09
Lower PCA memory test event
10
Line Frequency out of acceptable range
11
Watchdog (Upper PCA) low voltage power
12
Watchdog (Lower PCA) low voltage power
13
Fan at incorrect speed (version 1 treadmills)
14
Fan fail (Lower PCA)
15
AC input voltage too high
16
AC input voltage too low
17
Dynamic break resistor thermal trip (treadmill only)
18
Dynamic break resistor thermal switch open (treadmill
only)
19
Power factor corrector malfunction (treadmill only)
20
Motor will not start, or no motor movement was
detected (treadmills only); too many maximum power
requests in one second (other equipment)
21
Too many maximum consecutive power requests
22
No motor pulses at start up
23
Motor pulses missing after start up
24
Reduce speed requested, speed is not reducing
25
Lower drive hardware error (treadmill only)
26
Motor pulse width incorrect
27
Too much drive motor current
28
Temperature too high
29
Excessive AC input current
Summary of Contents for P30 Console