C554i Self Powered Elliptical Fitness Crosstrainer
Page 64
7.
Remove the ramp from the EFX.
8.
Remove the two bolts, wave washers and shims that fasten the ramp mounting bracket to
the frame. Remove the ramp mounting bracket.
9.
Set the replacement ramp mounting bracket at its mounting position. Fasten the ramp
mounting bracket with the hardware removed in step 8, slide the wave washer onto the bolt
and then the shim. Torque the bolts to 25 ft./lbs.
10. Set the replacement ramp in its mounting position, replace the bolts washers and nuts
removed in step 6. Do tighten the bolts at this time.
11. Replace the four bolts and washers removed in step 5 that fasten the ramp to the rear ramp
bracket.
12. Torque the four bolts between the ramp and rear ramp bracket to 12 ft./lbs. Torque the two
bolts between the ramp and the front ramp support to 20 ft./lbs.
13. Replace the ramp end cap with the screw removed in step 4.
14. Rotate both stairarms forward so that they are resting on the ramp.
15. Set the replacement right stairarm connector at its mounting position and slide the
secondary link onto the right stairarm connector. Replace, but do not tighten the hardware
removed in step 2. Torque the two bottom bolts to 50 in./lbs. Torque the horizontal bolt to 11
ft.lbs. Set the replacement left stairarm connector at its mounting position and slide the
secondary link onto the left stairarm connector. Replace, but do not tighten the hardware
removed in step 2. Torque the two bottom bolts to 50 in./lbs. Torque the horizontal bolt to 11
ft.lbs.
16. Replace the front, top, left and right cover sections per Procedure 7.17.
17. Thoroughly, test the EFX per Section Four.