Section Four - Checking EFX Operation
This section provides you with a quick method of checking EFX operation. Check the operation
of the EFX at the end of most maintenance procedures.
Procedure
1.
Start striding on the EFX or plug the optional external power supply (when available) into the
EFX and the AC outlet.
2.
When the
PRECOR
banner scrolling, press
QUICK START
.
3.
Select Resistance Level 1 and press
ENTER
.
4.
Operate the EFX for 4–5 minutes. As you operate the EFX, concentrate on the operating
sounds made by the unit. Be on the alert for unusual rubbing, hitting, grinding, or squeaking
noises.
5.
If the EFX makes unusual noises or the electronic display does not change appropriately,
troubleshoot per Section 6.
6.
Press the
RESISTANCE
key until you reach Resistance Level 10. Operate the EFX for
another 2–3 minutes.
7.
If the EFX resistance does not change or the operation of the EFX feels inconsistent
compared with Resistance Level 1, troubleshoot per Section 6.
8.
Press the
RESISTANCE
key until you reach Resistance Level 20. Operate the EFX for
another 2–3 minutes.
9.
If the resistance of the EFX 556 does not change or the EFX operation feels inconsistent
with Resistance Levels 1 and 10, troubleshoot per Section 6.
10. Check the LED’s mounted on the upper PCA and the function keys displayed on the
electronic console by performing Procedure 3.2.