C532i, C556i Navy Elliptical Fitness Crosstrainer
Page 57
Procedure 7.15 - Replacing a Ramp Assembly
Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch
points exist between the stairarm and ramp and between the stairarm and crankarm,
when the rear covers are removed.
1.
Pedal the EFX and press the QUICK START key, while striding on the unit raise the incline
to its maximum position.
2.
Remove the access panel, top, right and left rear covers per Procedure 7.1
3.
Remove both stairarms per Procedure 7.14.
4.
Remove the two bolts that fasten the lower rear portion of the ramp to the frame. See
Diagram 7.11.
Diagram 7.11 - Lower Ramp Mounting
5.
Remove the two bolts that fasten the upper end of the ramp to the lift motor yoke. See
Diagram 7.12.
6.
Carefully lift the ramp and slide it off of the lift motor yoke.
7.
Slide the replacement ramp onto the lift motor yoke and hand. Hand start the two lower
ramp mounting bolts removed in step 5. Fasten the upper end of the ramp to the lift motor
yoke with the hardware removed in step 6. Install and torque the two lower ramp bolts to 480
inch pounds (40 foot pounds).
Lower Ramp
Mounting Bolt