12. Press the CANCEL (C532i) key to proceed to the Metrics board SW display or the BACK
key (C556i Navy) to proceed to the serial number display, skip to step.16.
13. The display name “METRICS BOARD SW PART NUMBER will be displayed, press the OK
key, the metrics board software part number will be displayed.
14. Press the CANCEL (C532i) or the BACK (C556i Navy) key to proceed to the serial number
display.
15. The display name “SERIAL NUMBER” will be displayed, press the OK key, the serial
number will be displayed. If the serial number is not present it can be uploaded per
Procedure 2.5.
16. Press the CANCEL (C532i) or the BACK key (C556i Navy) key to proceed to the usage log
display.
17. The display name “USAGE LOG” will be displayed, press the OK key.
18. The program used and the time the program was used will be displayed.
19. The keys
,
will scroll you through the list of programs that have been used.
20. Press the CANCEL (C532i) or the BACK (C556i Navy) key to proceed to the error log
display.
21. The display name “ERROR LOG” will be displayed, press the OK key.
22. The first error log entry will be displayed “1: ERXX XX STRIDES XX HRS”.
23. Pressing the
,
keys will move you through the log entries. Press the OK key to view the
selected error. Entry 1 will be the most recent error log entry, with each succeeding entry
being older than the preceding entry.
24. If the error log is empty “NO ERRORS” will be displayed.
25. Pressing and holding the QUICK START key for 2 seconds will cause the prompt CLEAR?
to be displayed, holding the QUICK START for an additional 2 seconds will clear all existing
entries from the error log. The display will confirm that the error log has been cleared by
displaying OK. The display will revert to the first log entry and show it as a null entry (1: ---).
If the QUICK START key is not held for a minimum of 4 seconds, the error log will not be
cleared.