![PrecisionTemp RV-550 NSP-EC Installation, Operation And Maintenance Manual Download Page 7](http://html1.mh-extra.com/html/precisiontemp/rv-550-nsp-ec/rv-550-nsp-ec_installation-operation-and-maintenance-manual_1594623007.webp)
Burner Ignites But Water Temperature Is too low
1. The water flow may be so high as to exceed the
capacity of the heater particularly if your supply
water is very cold. Slow the water flow.
2. The gas pressure may be too low. Be sure the
gas flow control valve is in full “on” position.
3. Check the gas pressure while the water is on at full
flow. The LPG pressure should be the “manifold
pressure” as shown on the specification label while
the heater is running. A gas-testing gauge should be
installed on the manifold tap so that it may be read
while heater is running. If it is too low, turn up the gas
regulator to the proper pressure. This should only be
done by a qualified technician.
4. The gas flow may be too low due to improper gas
line diameter (under 3/8 inch outside diameter). The
gas line may be excessively long (over 20-30 feet) or
the on/off solenoid at the tank (if you have one) may
have an orifice that is too small (under 3/16th of an
inch).
5. Check the heater door louvers and flue pipe for
airflow obstructions and clean.
6. Check that the “summer / winter” valve is in the
proper position for the temperature of the incoming
water.
Water Temperature Is Too Hot or No Temperature
Control.
1. Fuel tank regulator is set too high and manifold
pressure as described above Have the regulator
checked by a qualified technician.
2. Water flow too low for incoming water temperature.
Low Heat Rise and Excessive Water Flow Is
Required To Trigger Water Heater
If you find that your heater requires excessive flow to
activate it (much over .5 gallon per minute), it is likely
that you have cold water bleeding into the hot water
side of your water system.
1. Check that valves and faucets are closed when
not in use. If there is an on/off button on your
showerhead, always turn the water valves off after
the shower to prevent cold water from bleeding into
the hot water system. This will keep the heater from
functioning properly.
2. Be sure that the bypass valve at the water plumbing
connections is in the "off" position. An open valve can
also permit water to bypass heater, causing it not to fire.
If any problem persists, contact an authorized service
center or
PrecisionTemp
.
PrecisionTemp, Inc.
WATER HEATER
LIMITED WARRANTY
PrecisionTemp, Inc warrants to the original owner and subject to the
below mentioned conditions, that this product will be free of defects in
material or workmanship for a period of two years from the original date of
purchase. PrecisionTemp’s liability hereunder is limited to the replacement of the
product, repair of the product, or replacement of the product with a reconditioned
product at the discretion of the manufacturer. This warranty is void if the product
has been damaged by accident, unreasonable use, neglect, tampering or other
causes not arising from defects in material workmanship.
This warranty extends to the original owner of the product only and is
subject to the following conditions:
1. For a period of two years from the date of purchase, PrecisionTemp will replace
the complete water heater if the heat exchanger leaks due to corrosion. This
warranty includes reasonable labor charges required to
replace the complete water heater.
2. For two years from the date of purchase, PrecisionTemp will repair or replace
any part defective in material or workmanship. This warranty includes reasonable
labor charges, required to remove and replace the part. Service calls to
customer’s location are not considered part of these
charges and are, therefore, the responsibility of the owner.
3. This warranty does not cover the following items classified as normal
maintenance:
a. adjustment of gas pressure
b. cleaning or replacement of burner orifices
c. cleaning or adjustment of burner assembly
d. cleaning or adjustment of flue
e. adjustment of pressure relief valve
4.
In the event of a warranty claim, the owner must contact, in
advance, either an authorized PrecisionTemp Service Center or the
PrecisionTemp Service Department. Warranty claim service must be
performed at an authorized PrecisionTemp Service Center (a list will be
provided at no charge) or as approved
, PrecisionTemp, Inc
11 Sunnybrook Dr. Cincinnati, OH 45237, 800-934-9690 Ext. 109. Return parts (or
water heater) must be shipped to PrecisionTemp “Prepaid”. The defective parts (or
water heater) become the property of PrecisionTemp and must be returned to the
Service Department,
PrecisionTemp, Inc. 11 Sunnybrook Dr. Cincinnati, OH 45237.
6. This warranty applies only if the unit is installed according to the installation
instructions provided and complies with local and state codes.
7. The warranty period on replacement parts (or water heater) is the
unused portion of the original warranty period or ninety (90) days,
whichever is greater.
8. Damage or failure resulting from misuse (including failure to seek proper repair
service), misapplication, alterations, water damage, or freezing are the owner’s
responsibility.
9. PrecisionTemp does not assume responsibility for any loss of use of vehicle,
loss of time, inconvenience, expense for gasoline, telephone, travel, lodging, loss
or damage to personal property or revenues. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitations or exclusions may not apply to you.
10. Any implied warranties are limited to two (2) years. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not
apply to you. This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.
11. Replacement parts purchased outside of the original water heater warranty
carry a 90 day warranty. This includes the part at no charge.
This PrecisionTemp heater is designed for use in recreational vehicles, park
models, mobile food carts and marine applications for the purpose of heating water
as stated in the “data plate” attached to the water heater. Any other use, unless
authorized in writing by the PrecisionTemp Engineering Department, voids this
warranty.
11 Sunnybrook Drive
Cincinnati, OH. 45237
Phone: 513-641-4446 * 800-934-9690
Fax: 513-641-0733