PrecisionTemp RV-550 NSP-EC Installation, Operation And Maintenance Manual Download Page 2

Cold In

Gas Connection

Hot Out

GENERAL INSTALLATION

The following instruction describes the most common type of 

installation for the water heater. The most common mounting 

location would be in the “basement” or luggage compartment.  

Consult your Field Auditor, Account Manager, or the 

PrecisionTemp Service Department if you have additional 

questions. 

Mounting Unit

Unit should be located to allow hookups on the back and 
access to the front panel for servicing.  Note the locations 
of the flue pipe, combustion air cut-outs and mounting 
holes  on the diagram below. The dotted line represents 
the base of the unit.  Be sure these holes will not interfere 
with any framing members or other wiring or equipment 
under the coach.  When the appliance is installed directly 
on carpeting, it shall be installed on a metal or wood panel 
extending beyond the full width and depth of the appliance 
by at least 3 inches (76.2 mm) in any direction.  

The 

appliance should be located in an area where leakage of 
the unit or connections will not result in damage to the 
area adjacent to the appliance or to lower floors of the 
structure. When such locations cannot be avoided, it is 
recommended that a suitable drain pan, adequately 
drained, be installed under the appliance. The pan must 
not restrict combustion air flow. 
Be sure to observe proper clearances around the unit. 
1. Referring to the diagram, locate the proper mounting 
location and cut a hole with a diameter of 4.25” to 
accommodate the flue pipe with at least 1” clearance 
completely around the flue pipe.  A 4.5” hole for the 
combustion air should be cut so that it is under the bottom 
air intake grill.  This hole must be located where it cannot 
be covered or blocked and to assure all combustion air 
comes from the outside.  
2.

Mount the 2 brackets to the bottom of the unit on 
either side using the supplied 1/4” bolts.  

3.

Place unit into place to locate 4 mounting holes and 
mark their positions. 

4.

Remove the unit and  drill the 4 – 3/8” mounting holes 
in the floor.  

5.

Apply a rubber gasket or sealant around the 
combustion air hole on the bottom of the unit and 
mount unit in place assuring the seal is in complete 
contact with the mounting surface to assure an air 
tight seal. Note: Do not use glue.  

6.

Screw or bolt into place.  

Exhaust Pipe Installation

After the unit is secured into place, the exhaust pipe is 
installed as follows:
1. Fit the long pipe / elbow onto the 2” flue tailpiece from 

the bottom of the unit and push flare side of the elbow 
up onto the flue tailpiece of the unit. 

2. Locate the pipe out from under the coach while 

positioning it so that it points about 30° to the rear of 
the coach.  Allow for at least 6” to protrude from under 
the coach.  

3. Now remove the pipe and coat the inside diameter of 

the flue pipe elbow with high temperature silicone 
sealant or equivalent.  

4. Locate pipe onto tailpiece and screw the elbow of the 

pipe to the tailpiece. This can be done with self-
tapping screws or by pre-drilling the hole before 
inserting metal screws.  At least two screws must be 
used to secure the pipe.  

5. Screw or clamp assembly into place and use a proper 

exhaust bracket to support flue pipe to the bottom of 
the coach.

7.  

Connect plumbing to water lines taking care to make 

correct “COLD” and “HOT” orientation. Connect 3/8” FM 
flared LP gas line to 3/8” M flared gas fitting. Assure the 
water and gas line grommets continue to be intact and 
properly inserted in the case holes, with no gaps or 
openings where the lines pass through the case. See 
illustration.

8. Turn on the gas and check the water heater and all 
connections for gas leaks with a leak detecting solution.
9. Turn on water supply line and check for water leaks.

All connections must be made using TWO 

(2) wrenches to avoid twisting and damaging 

lines. Damage voids the Warranty! 

2

4.5”

Flue Pipe Opening 

4.25”

Combustion Air 

Opening

4.5” Minimum

Gasket or Sealant between unit 

base and mounting surface

3/8” mounting hole X 4

Front access door-

do not block

Back - Allow enough clearance for hookups

9.0”

10.1”

6.25”

11.0”

13.5”

13.5”

Mounting Bracket X 2

9.5”

5.56

3.5”

1.5” HOLE 

1.625”

2.875”

Summary of Contents for RV-550 NSP-EC

Page 1: ...l codes the Standard on Recreational Vehicles NFPA1192 and or CAN CSA Z240 RV CLEARANCE Requirements SIdes top and bottom 0 Back Enough to make connections but no less than 2 5 Front Enough to remote...

Page 2: ...e unit and drill the 4 3 8 mounting holes in the floor 5 Apply a rubber gasket or sealant around the combustion air hole on the bottom of the unit and mount unit in place assuring the seal is in compl...

Page 3: ...odes or in the absence of local codes Standard on Recreational Vehicles ANSI A119 2 or CAN CSA Z240RV CAUTION ELECTRICAL DAMAGE Label all wires prior to disconnection when servicing controls Wiring er...

Page 4: ...water This cold water has to be purged from the line each time the shower head is turned back on Tests have shown that this will not save water and sometimes uses more water than leaving the shower r...

Page 5: ...or Flow Meter 2 Power Vent 3 Fluing Vacuum Switch 4 Combination Gas Valve 5 Igniter Proofing Probe 6 Manifold and Burner 7 Finned Tube Heat Exchanger 8 Flue Hood 9 Flue Pipe 10 T In Thermistor 11 T Mi...

Page 6: ...ctions is in the off position An open valve can also permit water to bypass heater causing it not to fire There Is No Ignition When Water Is On Power vent is running 1 Be sure the gas valve at the tan...

Page 7: ...he date of purchase PrecisionTemp will replace the complete water heater if the heat exchanger leaks due to corrosion This warranty includes reasonable labor charges required to replace the complete w...

Reviews: