ANNUAL SERVICE
In the interests of safety it is important that your
Precision Inset Boiler stove is serviced on an annual
basis in accordance with the instructions outlined
below. This should be carried out by a suitably
qualified person such as your original approved
installer, a Hetas or INFO registered installer or your
authorised Precision dealer.
When the stove is cold strip, clean and inspect it.
Internal Components
Remove and inspect the
following: Baffle Plate, Grate Assembly and Ash Pan.
Use a wire brush to clean the baffle plate and grate
assembly. Carefully wire brush the inside of the stove
which is essentially the outside of the boiler and
remove all ash and debris from inside the stove and
the ash pan chamber.
Check all parts for wear or damage and replace as
necessary. Re-fit all the internal parts.
Stove Glass
Check the glass for chips or cracks and
the glass seal condition and replace if necessary.
Thoroughly clean the stove glass on both sides.
Door Seal
Check that this makes an air-tight seal and
replace if necessary. Ensure that the new rope joint is
also in the middle at the base of the rope seal channel.
External Bodywork
All external surfaces should be
dusted with a soft cloth or light brush.
• Examine all paintwork for signs of wear and re-paint
these areas using an appropriate heat-resistant black
aerosol paint.
Warning: do not use the aerosol if the
stove is alight or hot.
• When the aerosol paint has dried, apply traditional
stove black polish to all painted surfaces
• Lightly oil the hinges and locking mechanism
Air Controls
When standing down at the end of
the heating season these should be left in the open
position to allow some movement of air which will
help avoid condensation and moisture building up
inside the stove and flue system. These can be closed
up to 50% if it gets too draughty.
Liner Connection
If a chimney liner has been
installed then if possible check that the liner is secure
and that the cement seal is still good. Repair any
crumbling or failed seals.
Important
In the interests of safety use only genuine
Precision replacement parts which are readily available
from your authorised dealer.
NB
It is advisable to have the chimney or flue system
swept at the same time.
33