background image

1

Telephone: 02 6299 3477     

     Email: [email protected]     

     PO Box 6321 Queanbeyan East NSW 2620, Australia

www.3p-australia.com.au

24/02/2011 

V1.0

Power Lead

Circuit Breaker

Constantly Powered

Sockets

Controlled Sockets

Mode LED

Mode Button

1

2

3

4

Controlled Laptop Charger

Part No: 800 - 410058

Current Rating: 10A

Voltage Rating: 230VAC 50 Hz

      N28070

www.3p-australia.com.au

Specifications

Model Number:

800-410058

Rating:

230 V AC @ 50Hz

Max Total Load:

10 Amps

Socket Rating

10 Amps

Mounting

19” mounting rails

Rack Space Requirement 1.5 RU

Conforms with AS/NZS 3197 in conjunction with AS/NZS 3100

C-Tick Compliant

 

         N28070

Sockets:

Constantly Powered: 

 

2

Controlled: 

  4

Figure 1:

      Controlled Laptop Charger

Mode

Description

Mode Display

Disabled

All controlled sockets are off with power 
only to the constantly powered sockets.

Mode LED flashes once every 4 seconds to 
indicate unit power

Staged On

All sockets are enabled after staged 
powering of controlled sockets 1-4, with 
approximately a 1.5 second delay between 
sockets

Mode LED is constant

Constant Cycle

The controlled sockets are cycled 
continuously in order from socket 1 to 4.  
Each socket will be powered for a period 
of 1 hour before progressing to the next 
socket. 

The Mode LED will flash constantly, being on 
and off for equal periods of half a second.

12h Cycle

Cycles through controlled sockets 
powering each single socket for a period of 
t hours once every 12 h cycle. Options of 1 
or 2 hour periods.

The Mode LED will flash 1 to 2 times
followed by a 2 second pause.  The number 
of flashes corresponds to the time period 
each socket is powered.

Table 1:

      Modes (For controlled sockets only)

Summary of Contents for 800-410058

Page 1: ...Controlled Laptop Charger Instruction Manual Telephone 02 6299 3477 Email sales 3p australia com au PO Box 6321 Queanbeyan East NSW 2620 Australia www 3p australia com au ...

Page 2: ...Display Disabled All controlled sockets are off with power only to the constantly powered sockets Mode LED flashes once every 4 seconds to indicate unit power Staged On All sockets are enabled after staged powering of controlled sockets 1 4 with approximately a 1 5 second delay between sockets Mode LED is constant Constant Cycle The controlled sockets are cycled continuously in order from socket 1...

Page 3: ...ontrolled socket by up to 91 7 of that of a constantly powered socket Installation The installation procedure for the Controlled Laptop Charger is as follows 1 If rack mounting is desired the Controlled Laptop Charger may be screwed directly onto 19 mounting rails using two M6 screws and cages nuts on each side Two mounting configurations are possible for the 1 5 RU power board Use either the top ...

Page 4: ...to Stage On or powering on the PDU whilst in this mode the controlled sockets will power on in series with an approximate 1 5 second delay Once all sockets are on they will remain powered Mode 3 Constant Cycle 1 Hour period Once set or powering on the PDU whilst in this mode the PDU will cycle through each of the controlled sockets sequentially providing power for a period of 1 hour Once the 4th s...

Page 5: ... the controlled sockets sequentially providing power for a period of 1 hour Once the 4th socket has completed its 1 hour period all controlled sockets will remain unpowered for the remainder of the 12 hour cycle 8 hours Mode 5 12h Cycle 2h period This mode behaves the same as mode 4 however this mode powers each of the controlled socket for a period of 2 hours therefore leaving the controlled sock...

Reviews: