WARNING
Do not connect or disconnect under load.
Ensure driver has not been powered for a minimum of 1 minute before reconnecting the
LED module after disconnecting. Do not hot plug. Failure to follow this instruction will lead to
serious damage of the LED module and driver and will not be covered by warranty.
NOTE
LED module is not site serviceable.
Tampering will cause damage and will not
be covered by warranty.
NOTE
Maintain correct polarity when wiring. Incorrect wiring will cause serious damage and
will not be covered by warranty. Must be installed according to SELV regulations.
Wire specification: 22 AWG, ø0.65mm diameter double insulated teflon wire.
Red - Positive
Black - Negative
2. Changing the optics
WARNING
luminaire may be hot.
Allow to cool before touching.
Remove the luminaire from the ceiling.
Using the slot on the side of the
Magnetic Front Plate remove the plate.
We recommend using a screwdriver for
leverage.
Remove the optics and replace with
the new selection. To position the new
optics correctly place the optics into the
cover and replace.
Screw the optic holder back in to place
using the 2 cross head screws.
Reinstall onto ceiling as per step 1.
3. Using Accessories
WARNING
luminaire may be hot.
Allow to cool before touching.
Using the slot on the side of the
Magnetic Front Plate remove the plate.
We recommend using a screwdriver for
leverage.
Insert accessory into Magnetic Front
Plate and replace Front Plate into the
main body.