![PRECISION DIGITAL PD603 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/precision-digital/pd603/pd603_instruction-manual_1594087007.webp)
Sabre P
●
Model PD603 Process Meter Instruction Manual
7
ENCLOSURE
1/8 DIN, high impact plastic, UL 94V-0, color: gray
MOUNTING
1/8 DIN panel cutout required. Two panel mounting
bracket assemblies provided
TIGHTENING
TORQUE
Screw terminal connectors: 4.5 lb-in (0.5 Nm)
OVERALL
DIMENSIONS
2.45" x 4.68" x 4.19" (62 mm x 119 mm x 106 mm)
(H x W x D)
WEIGHT
8.5 oz (241 g)
WARRANTY
1 year parts & labor
EXTENDED
WARRANTY
1 or 2 years, refer to the Price List for details.
Process Input
INPUTS
Field selectable:
0-20, 4-20 mA, 0-5, 1-5, 0-10 V, or
±
10 V
ACCURACY
±0.05% FS ±1 count
FUNCTION
Linear
TEMPERATURE
DRIFT
50 PPM/
°
C from 0 to 65
°
C ambient
DECIMAL POINT
Up to three decimal places:
d.ddd
,
dd.dd
,
ddd.d
,
or
dddd
CALIBRATION
RANGE
An
Error
message will appear if input 1 and input 2 signals
are too close together.
Input
Range
Minimum Span
Input 1 & Input 2
4-20 mA 0.40 mA
±
10 V
0.20 V
INPUT
IMPEDANCE
Voltage ranges: greater than 1 M
Ω
Current ranges: 50 - 100
Ω
(depending on resettable fuse impedance)
INPUT
OVERLOAD
Current input protected by resettable fuse.
Fuse resets automatically after fault is removed.