Model PD6300 Pulse Input Rate/Totalizer
Instruction Manual
47
Gate Settings
Slow Pulse Rate
Low Gate* (sec)
High Gate (sec)
Min Freq** (Hz)
1.0 2.0 0.5000
1.0 10.0 0.1000
1.0 20.0 0.0500
1.0 100.0 0.0100
1.0 200.0 0.0050
1.0 400.0 0.0025
1.0 800.0 0.0012
1.0 999.9 0.0010
*The low gate setting corresponds to the display update rate and is
used to stabilize the display reading with a fluctuating signal.
**The minimum frequency is dependent on high gate setting.
Contact De-Bounce Filter (
FiLter
)
The filter function (
FiLter
) can be used for applications where the meter
is set up to count pulses generated by switch contacts. The filter value
can be set anywhere between 2 and 50, the higher the value, the greater
the filtering.
The filter function (
Filter
) is the second option in the Advanced Fea-
tures menu. There are two settings,
Hi SPd
(high speed) and
Lo SPd
(low speed), press
ENTER
when
Lo SPd
is displayed to enable the filter
function. Program the filter value, so that there are no extra counts when
a contact closure is completed.
Filter Settings
Contact De-Bounce Filter
Filter Setting
Speed Setting
Max Freq (Hz)
2 Lo
SPd 999
4 Lo
SPd 499
8 Lo
SPd 249
16 Lo
SPd 124
32 Lo
SPd 62
40 Lo
SPd 50
50 Lo
SPd 40
N/A Hi
SPd 30,000