5

 

 

Safety Information 

 

  Read complete instructions prior to installation 

and operation of the device. 

 

  Read all product labels completely and follow all 

instructions and requirements listed on the labels 

for installation or service. 

  Installation and service should be performed only 

by trained service personnel. Service requiring 

replacement of internal components must be 

performed at the factory. 

Installation 

All pushbuttons and wiring connectors are accessed 

by opening the enclosure. To access electrical con-

nectors, remove the 2 captive screws and remove the 

display assembly. Pushbuttons may also be accessed 

using the magnet assembly if reed switches are in-

stalled. 

Unpacking 

Remove both units from box. Inspect the packaging 

and contents for damage. Report damages, if any, to 

the carrier. If any part is missing or the units malfunc-

tion, please contact your supplier or the factory for as-

sistance. 

Pre-Installed Conduit Plug 

The PDW30-RNA is supplied with one pre-installed 

optional conduit plug for installations that do not re-

quire the use of both conduit entries. The conduit plug 

includes an internal hexagonal socket recess for re-

moval.  

Mounting Instructions 

The PDW30-RNA has two mounting holes that may 

be used for a 1.5" pipe mounting or wall mounting. 

Alternatively, the unit may be supported by the con-

duit using the conduit holes provided. The antenna is 

threaded into one of the three conduit holes and may 

be moved as appropriate for the installation. 
It can also be mounted by using the PDA6963 mount-

ing bracket in order to orient the device antenna away 

from the pipe. Refer t

Mounting Dimensions

 on page 

6

 for details on wall or panel space requirements. 

Cover Jam Screw 

The cover jam screw should be properly installed 

once the wireless units have been wired and tested in 

a safe environment. The cover jam screw is intended 

to prevent the removal of the units’ cover while in op-

eration without the use of tools. Using a M2 hex 

wrench, turn the screw clockwise until the screw con-

tacts the unit. Turn the screw an additional 1/4 to 1/2 

turn to secure the cover. 

 

  Excess torque may damage the threads and/or 

wrench. 

 

FCC Notice 

Contains FCC ID: MCQ-XB900HP 
The enclosed device complies with Part 15 of the 

FCC Rules. Operation is subject to the following two 

conditions: (i.) this device may not cause harmful in-

terference and (ii.) this device must accept any inter-

ference received, including interference that may 

cause undesired operation. 

Summary of Contents for PDW30-RNA

Page 1: ...01 Fax 508 655 8990 www predig com Wireless Repeater Unit in a Rugged Industrial Housing Simple to Order Configure Install Increase Range an Additional 1 Mile Line of Sight 500 Ft Indoor Remote or Att...

Page 2: ...tory Precision Digital s liability under this limited warranty shall not exceed the purchase value repair or replacement of the defective unit See Warranty Information and Terms Conditions on www pred...

Page 3: ...pe Mounting Kit 6 Mounting Dimensions 6 Connections 7 Wiring Diagram 7 Power Connector 7 Setup and Programming 8 Overview 8 Buttons Display 8 Programming Buttons 8 PDW Manager Software 9 Setup Menu 9...

Page 4: ...AWG wire Enclosure Cast aluminum with glass window 0 30 max copper content corrosion resistant powder coating color blue NEMA 4X IP68 Two NPT threaded conduit openings One NPT stainless steel conduit...

Page 5: ...internal hexagonal socket recess for re moval Mounting Instructions The PDW30 RNA has two mounting holes that may be used for a 1 5 pipe mounting or wall mounting Alternatively the unit may be support...

Page 6: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna...

Page 7: ...ures codes Observe all safety regulations Electrical wiring should be performed in accordance with all agency requirements and applicable national state and local codes to prevent damage to the device...

Page 8: ...nu item or option you want During number entry use the Next button to select a digit and the Previous button to increment the se lected digit Button Symbol Description Menu Enter or exit the device me...

Page 9: ...ireless units can be found under Programming with PDW Manager on page 11 Setup Menu The setup menu consists of network ID password and factory defaults restoration Entering Numeric Values Numeric valu...

Page 10: ...red to enter that password before being al lowed to access the device menu Note Setting a password will require you to enter the password to access the device settings via the PC software as well Did...

Page 11: ...be found on the included CD or downloaded from www predig com pdwmanager Once the soft ware is running power the unit using a 12 28 VDC power supply and connect the device to the PC using the provide...

Page 12: ...el mask may also be set for interference immunity The encryption key and channel mask may be entered on the Advanced tab Once you have entered the encryption information click Save Settings The wirele...

Page 13: ...predig com LIMW30R_C SFT102 Ver 1 000 up 06 20 Contact Precision Digital Technical Support Call 800 610 5239 or 508 655 7300 Fax 508 655 8990 Email support predig com Sales Support Call 800 343 1001...

Reviews: