Helios PD2-6262 Dual Analog Input Rate/Totalizer
Instruction Manual
58
Factory Defaults & User Settings
The following table shows the factory setting for most
of the programmable parameters on the meter.
Factory Defaults & User Settings
Parameter
Display
Default Setting
Input type
Input
Input type, channel A
Ch-A
4-20 mA
Input type, channel B
Ch-B
4-20 mA
Total, channel A
Ch-A
Yes
Total, channel B
Ch-B
Yes
Units
units
Rate unit, channel A
Ch-A
mA-A
Rate unit, channel B
Ch-B
mA-b
Unit, channel C
Ch-C
mA-C
Total unit, channel A
Tot-A
tot-A
Grand total unit, ch-A
Gtot-A
Gtot-A
Total unit, channel B
Tot-b
tot-b
Grand total unit, ch-B
Gtot-b
Gtot-B
Decimal Point
Dec pt
Rate, channel A
rate
3
Total, channel A
Total
1
Grand total, channel A
gtotal
0
Rate, channel B
rate
3
Total, channel B
Total
1
Grand total, channel B
gtotal
0
Channel C
Ch-C
3
Number of points
No pts
Number of points, ch A
Ch-A
2
Number of points, ch B
Ch-B
2
Scaling, (channel A)
Scal a
Input 1, channel A
InP 1
4.000 mA
Display 1, channel A
Dis 1
4.000
Input 2, channel A
InP 2
20.000 mA
Display 2, channel A
Dis 2
20.000
Scaling (channel B)
Scal b
Input 1, channel B
InP 1
4.000 mA
Display 1, channel B
Dis 1
4.000
Input 2, channel B
InP 2
20.000 mA
Display 2, channel B
Dis 2
20.000
Total setup
Tsetup
Time base, channel A
Tbase
Sec
Total conversion factor,
Ch-A
T CF
1.000
Grand total conversion
factor, Ch-A
Gt CF
1.000
Time base, channel B
Tbase
Sec
Factory Defaults & User Settings
Parameter
Display
Default Setting
Total conversion factor,
Ch-B
T CF
1.000
Grand total conversion
factor, Ch-B
Gt CF
1.000
Total reset
Treset
Total reset, channel A
T rst
Manual
Grand total reset, Ch-A
Gt rst
Manual
Total reset, channel B
T rst
Manual
Grand total reset, Ch-B
Gt rst
Manual
Display assignment
Dsplay
Display line 1
D Ch-A
Channel A
Display line 2
d Ch-B
Channel B
Display intensity
d-Inty
6
Relay
Relay
Relay 1 assignment
Ch-A
Channel A total
Relay 1 action
Act 1
Automatic
Relay 1 set point
Set 1
100.0
Relay 2 assignment
Ch-A
Channel A total
Relay 2 action
Act 2
Automatic
Relay 2 set point
Set 2
200.0
Relay 3 assignment
Ch-A
Channel A rate
Relay 3 action
Act 3
Automatic
Relay 3 set point
Set 3
3.000
Relay 3 reset point
RSt 3
2.500
Relay 4 assignment
Ch-A
Channel A rate
Relay 4 action
Act 4
Automatic
Relay 4 set point
Set 4
4.000
Relay 4 reset point
RSt 4
3.500
Fail-safe relay 1 to 4
Fls 1
Off
On delay relay 1 to 4
On 1
0.0 sec
Off delay relay 1 to 4
Off 1
0.0 sec
Loop break relay 1 to 4
ignore
Ignore
Analog output
Aout
Display 1 analog out
Dis 1
4.000
Output 1 value
Out 1
4.000 mA
Display 2 analog out
Dis 2
20.000
Output 2 value
Out 2
20.000 mA
Source analog output
Source
Channel A
Overrange output
O-rang
21.000 mA
Underrange output
u-rang
3.000 mA
Loop break output
break
3.000 mA
Maximum output
nmAx
23.000 mA
Minimum output
nmin
3.000 mA
Filter