Compressor
control
13
Compressor control
For compressor control, proceed as follows:
Prepare the compressor as described above, starting from page 10.
Switch on pressure reducer (2) by turning it counterclockwise.
Define allowable operating pressure of your edge device (pneumatic staple gun, painting gun, pneumatic
device for nailing, etc.)
Connect pressure hose of edge device to the union nipple (5).
Raise button (1) of pressure relay to start the compressor.
Wait until manometer (3) will not show the maximum operating pressure of appropriate compressor. Set
the allowable operating pressure of your edge device on pressure reducer (2).
o
Turn clockwise increases pressure.
o
Turn counterclockwise lowers pressure.
Turn of reducer on 90° changes operating pressure on about 0.5 bar
Operating pressure of edge device is reflected on the manometer (4).
The compressor starts automatically again as soon as pressure in the receiver falls after relief to starting
pressure (6-7 bar). This process is controlled automatically by pressure relay.
ATTENTION!
In case of overload the compressor can be damaged.
Do not overload the compressor: Do not exceed the ratio of operating time and downtime! See the tech-
nical specifications, starting from page 7.
WARNING
Explosion risk by excess of the maximum allowable operating pressure.
Define characteristics of your edge device before compressor connecting.