MT4000-2 MT10000-4
ISMTUK_06_06.doc
Pag. 11
3.2. Installation example with automatic door
A typical automatic door-control installation is made up as follows:
•
1 in reader;
•
1 out door-opening push-button;
•
1 automatic door.
Connect entrance reader 1 to terminals D0.1, D1.1, GND, and +9V of the control unit.
Connect the automatic door triggering contact to terminals NO1 and COM1.
Connect the manual door opening button between terminals IN1 and +9V of the control unit.
Using SWAMIGO software:
Duly configure reader 1 for relay 1 tripping
Duly configure the IN1 input for relay 1 tripping
Set relay 1 tripping and delay times to 1 and 0 seconds, respectively
Programme a badge for default access enable (5 Control Unit programming and testing, pag. 16)
Automatic door opens after 1 second following valid read or pushing of manual opening out button.
Note: the figure shows the wiring with the MT10000-4 control unit terminal board but can easily be
applied to an installation with the MT4000-2 control unit.