17
www.praher.com
•
Put in the mounting bracket of the battery and tight it with the screw
(tightening torque 0,3Nm)
•
Connect the accumulator with the circuit board SafetyPack.
•
Put the cover onto the Aquastar and fix it with the 6 screws.
•
Connect the Aquastar to the power supply.
•
The green LED of the SafetyPack indicates that the accumulator is ready for
operation (if not please read problem detection under 9.1 LED-display).
•
Valve is now ready for use.
Further information regarding operation mode of SafetyPack please read chapter 9
operation mode Aquastar SafetyPack.
11. Circuit Board Aquastar SafetyPack
(1) Terminal for accumulator
(2) Interface for circuit board of the Aquastar Comfort
(3) LEDs
(4) Screws
(5) Switch ON / OFF for accumulator
•
Disable SafetyPack (Disconnect the accumulator)
1
5
3
4
4
2