TRANSMETTEUR 2-FILS
UNIVERSEL (Pt100/TC)
PRetop 5331
SOMMAIRE
Consigne de sécurité ......................................................... 26
Déclaration de conformité CE ............................................ 27
Application ......................................................................... 28
Caractéristiques techniques .............................................. 28
Montage / installation ......................................................... 28
Applications ........................................................................ 29
Référence ........................................................................... 30
Spécifications électriques .................................................. 30
Connexions ........................................................................ 34
Schéma de principe ........................................................... 35
Programmation ................................................................... 36
Dimensions mécaniques .................................................... 36
Montage des fils du capteur .............................................. 36
Appendix:
FM Installation Drawing No. 5300Q502 ............................. 50
CSA Installation Drawing No. 533XQC03 .......................... 52
25
Programming:
• Loop Link is a communications interface that is needed for programming
PRetop 5331.
• For programming please refer to the drawing below and the help functions in
PReset.
• Loop link is not approved for communication with modules installed in
harzard ous (Ex) areas
Order: Loop Link
Mechanical specifications:
Mounting of sensor wires
24
PRetop 5331
1
2
File Product In
put Output Com
munication Lang
uage Option
08:30:00
PRetop 5331
Date:
1994-8-10
943201594
PRelectronics
Analog input
Analog output
Serial no:
Input type:
Output type:
4 - 20mA
Upscale
Sensor error:
Pt100 DIN/IEC
0.00 - 50.00 C
3-wire
1.00 sec
------
Input range:
Connection:
Cold junction co
mp:
Response time
:
Tag no:
*
*
COM
Loop Link
Disconnect
+Vsupply
* Connected only for
on-line programming
Black
Red
Yellow
Green
Input
Receiving
Equipment
Connector
Wires must be mounted between the metal
plates.