5331V114-UK
5
Effect of supply voltage variation
.................... < 0.005% of span / VDC
Vibration
...................................................................... IEC 60068-2-6 : 2007
2...25 Hz
.............................................................
±1.6 mm
25...100 Hz
.................................................. ±4 g
Max. wire size
............................................................ 1 x 1.5 mm
2
stranded wire
Screw terminal torque ........................................... 0.4 Nm
Humidity
......................................................................
< 95% RH (non-cond.)
Dimensions ................................................................. Ø 44 x 20.2 mm
Protection degree (enclosure / terminal)
....... IP68 / IP00
Weight
.......................................................................... 50 g
Electrical specifications, input:
RTD and linear resistance input:
Max. offset ................................................................. 50% of selec. max. value
Cable resistance per wire (max.)
....................... 5
Ω
Sensor current ........................................................... Nom. 0.2 mA
Effect of sensor cable resistance
(3- / 4-wire)
................................................................ < 0.002
Ω/Ω
Sensor error detection ........................................... Yes
Basic values
Input type
Basic
accuracy
Temperature
coefficient
RTD
≤
±0.2°C
≤
±0.01°C/°C
Lin. R
≤
±0.1
Ω
≤
±10 m
Ω
/ °C
Volt
≤
±10 µV
≤
±1 µV / °C
TC type:
E, J, K, L, N, T, U
≤
±1°C
≤
±0.05°C / °C
TC type: B, R, S,
W3, W5, LR
≤
±2°C
≤
±0.2°C / °C
EMC immunity influence
................................................ < ±0.5% of span
Extended EMC immunity:
NAMUR NE
21, A criterion, burst
............................... < ±1% of span
RTD
type
Min.
value
Max.
value
Min.
span
Standard
Pt100
Ni100
Lin. R
-200°C
-60°C
0
Ω
+850°C
+250°C
5000
Ω
25°C
25°C
30
Ω
IEC 60751
DIN 43760
-----