2204V104-UK 7
Output
The output can be ordered for standard currents and voltages or special
versions within the signal range.
Standard output current
(pin 3) 0/4...20 mA and 0/1...5 mA acc. to order schedule
with the possibility of reversal. Current limit: 23...28 mA.
Standard voltage output
(pin 2) is achieved by short-circuiting pins 2 and 3. The
current signal is available between pins 2 and 1. For voltage signals in the range
0...1 VDC, a 50
Ω
shunt (DP 2-1) is applied; in the range 0...10 VDC, a 500
Ω
shunt
(DP 2-2) is applied. If both signals are used simultaneously, the mA loop to ground
must go through the internal shunt. Adjustment of 0 and 100% is possible in the
front ±10%, but please note that the basic calibration is thereby lost.
Electrical specifications
Specifications range:
-20°C to +60°C
Common specifications:
Supply voltage, DC .................................................. 19.2...28.8 VDC
Supply voltage, universal ..................................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Max. consumption 2204--D (24 VDC) .............
≤
1.3 W
Max. consumption 2204--P (uni. supply) .......
≤
1.8 W
Isolation, test / operation ..................................... 3.75 kVAC / 250 VAC
Signal / noise ratio .................................................. Min. 60 dB
Response time (0...90%) ....................................... < 25 ms
Temperature coefficient ........................................ < ±0.01% of span/°C
Linearity error ........................................................... < ±0.1% of span
Effect of supply voltage change ....................... < ±0.002% of span/%V
EMC immunity influence ...................................... < ±0.5% of span
Relative air humidity .............................................. < 95% RH (non cond.)
Dimensions (HxWxD) .............................................. 80.5 x 35.5 x 84.5 mm
Protection degree .................................................... IP50
Weight DC / universally supplied ...................... 110 g / 160 g