The following points are important for safety as well as for the smooth 
installation and performance of the unit. 

 
When unpacking and before disposing of the package check there is no transportation damage before 
using the projector. Should there be any damage caused by transportation, consult your dealer and do 
not use the apparatus. Keep the package well for your possible future transportation. 
 
The projector is for indoor use only, IP 20. Use only in dry locations. Keep this device away from rain 
and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other fluids, or 
metallic objects. 

The projector is not designed or intended to be mounted directly on to inflammable surfaces. 

 

 
The projector is only intended for installation, operation and maintenance by qualified personnel. 
 
The projector must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces. Be sure that all the cooling fans run normally and no ventilation slots are blocked. 
 
Do not project the beam onto inflammable surfaces, minimum distance is 3m. 

 3m   

 
Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 
 
Do not attempt to dismantle and / or modify the projector in any way. 
 
Electrical connection must only be carried out by qualified personnel. 
 
Before installation, ensure that the voltage and frequency of power supply match the power 
requirements of the projector. Only use the lamp with the specified type and rating. 
 
It is essential that each projector is correctly earthed and that electrical installation conforms to all 
relevant standards. 
 
Do not connect this device to any dimmer pack. 
 
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the power-cord 
come into contact with other cables. Only handle the power-cord by the plug. Never pull out the plug 
by tugging the power-cord. 
 
Keep the lamp clean. Do not touch the lamp glass with bare hand. 
 
The lamp used in this projector is an high power discharge lamp. After being switched off don’

t attempt 

to restart the projector until lamp has cooled, this will require approx 15 minutes. Switching the lamp on 
and off at short intervals will reduce the life of both the lamp and the projector. Occasional breaks will 
prolong the life of both the lamp and the projector. 
 
Never run the projector without a lamp. 
 
There are no user serviceable parts inside the projector, do not open the housing and never operate 
the projector with the covers removed. 
 

Always disconnect from the mains, when the device is not in use or before cleaning it 
or before attempting any maintenance work.  

 
If you have any questions, don’

t hesitate to consult your dealer or manufacturer. 

 
 

SAFE USAGE OF THE PROJECTOR 

Summary of Contents for Theatre Master PR-3010

Page 1: ...nformation about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin R...

Page 2: ...er and or dealer THESE ITEMS ARE PACKED TOGETHER WITH THE PROJECTOR Bracket 1 PCS Locking knob 2 PCS XLR plug 1 PCS XLR socket 1 PCS This manual 1 PCS Thank you for purchasing the product Theatre Mast...

Page 3: ...nnection must only be carried out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the projector Only use the lamp with...

Page 4: ...over and tighten the M4 knurled screw NOTE The HMI series are high pressure lamps with external igniters Care should always be taken when handling these lamps Always read the manufacturers Instruction...

Page 5: ...and from the projector is via cannon 3 pin XLR plugs and sockets which are included with the projector The XLR s are connected as shown in the table above Note care should be taken to ensure that none...

Page 6: ...nnector with a 120 ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in the chain The connections are illustrated below CONNECTING CONTROLLE...

Page 7: ...9 and 10 switches on the OFF 9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Setting Table of Address Switches 8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 OFF 7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 ON 6 0 1 0 1 0 1 0 1 0 1 0...

Page 8: ...fuse of the same specified value 20A 250V fast blow 6mmx30mm On the main PCB inside the projector there is also a fuse rated 2A 250V fast blow 5mmx20mm Should these be damaged call a qualified technic...

Page 9: ...ife Power supply 230V AC 50Hz Optional 240V 220V 200V AC 50 60Hz Power consumption 1400W at 220V Lamp HMI 1200W double ends Colours 7 didichroic colours white Rainbow effect at variable speeds Iris Co...

Page 10: ...10 12 Theatre Master manual doc LIGHT OUTPUT ELECTRICAL DIAGRAM...

Page 11: ...11 12 Theatre Master manual doc...

Page 12: ...12 12 Theatre Master manual doc PR LIGHTING LTD Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 020 8478 1888 FAX 020 8478 6023 P N 320040026 Last Revision 24 02 2004...

Reviews: