9/30
●
GOBO REPLACEMENT
DANGER!
Before replacement of gobos, the projector must be off the power.
2. Remove the lamp's two wires and push
it obliquely for the removal.
2.Remove the cover after its 4 screws are
loosened by a cross screwdriver
4.Connect the lamp wires after a new lamp is in place,
and align and tighten the lamp as per figure2
Figure3
:
Removal of lamp
1.Loosen a tightening screw at the lamp's side
Figure 2
Figure 2
Rotating gobo wheel
Rotator
Gobo
Tightening
spring
Gobo replacement
1. As shown in figure1, disconnect a projector from power. Unfasten
the 4 fastfit screws of the cover to remove the cover, and unfasten
the 2 screws of the fan assembly and remove the assembly.
2.Pull out the rotator from the rotating gobo wheel forcefully by
fingers as shown in figure2 After replacing the gobo or the rotator,
put the rotator back to the holder.
unfasten 2
screws using a
cross screw
driver
remove the fan
component
Figure 1