![PR Lighting CSL 1037 Manual Download Page 8](http://html1.mh-extra.com/html/pr-lighting/csl-1037/csl-1037_manual_1593134008.webp)
8/14
TO SET THE DMX START ADDRESS
Each unit must be given a DMX start address so that the correct unit responds to the correct control signals. This DMX start address is
the channel number from which the unit starts to “listen” to the digital control information being sent out from the controller. The unit
has 2 DMX channels, so set the No. 1 unit’s address 001, No. 2 unit’s address 003, No. 3 unit’s address 005, and so on.
While the display is locked( initial stage of the display), press the
FUNC for more than 3 seconds to unlock it,
Press
FUNC to locate
menu
Press ENTER to show DMX address
Press UP or DOWN to set or change parameters
While the set address is flashing, press ENTER to confirm. After this, the start address has been automatically stored. After
power-on next time, the latest number will be shown.
Press FUNC to go back t o1st level menus
Operations Menu
1
ST
Level menu
2
nd
level menu
3
rd
level menu
Remarks
DMX Address
(
ADDR
)
XXX
(
DMX
:
001~512
)
DMX
Address
Configuration
(
CNFG
)
Display settings
(
DISP
)
(
Default
:
ON
)
(ON)
Digital Display always
on
(
OFF
)
The digital display off
3 minutes after no
buttons are pressed
after the exit of the
menus
Dimmer
(
DIMM
)
000-255
From Dark to Bright
Brightness Value
Displayed
Information
(
INFO
)
Fixture’ s temperature
(
TEMP
)
XXX Fixture’s
Temperature
Fixture’s hours
(
TIME
)
XXXX Fixture’s
use
time
Software Version
(
VER
)
X.X.X Version
Displayed
DMX PROTOCOL
CHANNEL FUNCTION
DMX
DESCRIPTION
1
Dimmer
000-255
From dark to bright
2 Strobe
000 - 007
NO strobe
008 - 255
Strobe speed from slow to fast
Summary of Contents for CSL 1037