background image

                                                   

 Century Spot manual_Last Revision_en.doc 

9/14 

 
 

If the lamp becomes damaged or deformed in any way it must be replaced. If the light from the 
lamp appears dim this would normally indicate that it is reaching the end of its life and it should be 
changed at once, old lamps run to the extremity of their life may explode. If the projector does not 
function, check the fuse in the projector base. It should only be replaced by fuse of the same 
specified value 16A/380V (fast blow, ceramic). On the main PCB inside the projector there is also 
a fuse rated 4A/250V (fast blow, 5mmx20mm). Should these be damaged call a qualified 
technician before replacement. The projector has thermal protection device that will switch off the 
projector in case of overheating, should this operate, check that the fans are not blocked, and if 
they are dirty clean them before switching on the projector again. Check that the fans are 
operational. 

Any maintenance work should only be carried out by a qualified technician. 

 
 
 

To ensure the reliability of the projector it should be kept clean. It is recommended that the fans 
should be cleaned every 15 days. The dichroic colour filters should also be regularly cleaned to 
maintain an optimum light output. 

Do NOT use any type of solvent on dichroic colour filters. 

Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or 
particularly dirty surroundings can cause greater accumulation of dirt on the unit’

s optics. A soft 

cloth and typical glass cleaning products should be used in cleaning.  

Do not use any organic solvent, e.g. alcohol, to clean the housing of the 
projector. 

 
 
 

PROBLEM 

ACTION 

The projector doesn’

t work 

Check the fuse on the power socket. 
Replace the lamp. 

The lamp comes on but the projector 
doesn’

t respond to the controller 

Make sure that the projector is correctly 
configured. 
Replace or repair the DMX cable. 

The projector only functions intermittently 

Make sure the fan is working and not dirty. 

Defective projection 

Check the lenses are not broken. 
Remove dust or grease from the lenses. 

The projected image appears to have a 
halo 

Make sure the lamp is installed correctly. 
Carefully clean the optical group lenses and the 
projector components. 

The beam appears dim 

Check the optics is clean. 
Replace with a new lamp of the specified type and 
rating. 

 
LIGHT OUTPUT

 

 

MAINTENANCE 

TROUBLESHOOTING 

KEEPING THE PROJECTOR CLEAN 

Summary of Contents for CENTURY SPOT

Page 1: ...formation about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin Ro...

Page 2: ...be any damage caused by transportation consult your dealer and do not use the apparatus But any damage caused by improper use will not be assumed by the manufacturer and or dealer THESE ITEMS ARE PAC...

Page 3: ...ed out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the projector Only use the lamp with the specified type and rati...

Page 4: ...he beam path Don t touch the bulb by bare hand Close the dichroic colour filter bracket and install projector head cover Make sure that all screws and retaining clips are tightened Note The HMI series...

Page 5: ...confirm The green LED will flash one time which means that apparatus has saved your setting The setting will be displayed when you turn on next time In stand alone mode the DMX start address could be...

Page 6: ...th each core having at least a 0 5mm diameter Connection to and from the projector is via an XLR control cable with 3 pin plug and socket which are included with the projector The XLR s are connected...

Page 7: ...ons are illustrated below Many luminaires can run synchronously by linking them with each other in the master slave mode Set the address of all luminaires to 001 Select one luminaire as the master and...

Page 8: ...Connect the controller s output to the 1st luminaire s input and connect the 1st luminaire s output to the 2nd luminaire s input The rest may be connected in the same way Eventually connect the last l...

Page 9: ...hould be cleaned every 15 days The dichroic colour filters should also be regularly cleaned to maintain an optimum light output Do NOT use any type of solvent on dichroic colour filters Cleaning frequ...

Page 10: ...0 K Manufacturers Rated Lamp life 500 Hours Protocol Standard DMX 512 Running mode Stand alone Master Slave and DMX Controller DMX channels 6 channels Colours 3 basic colours CYM 256 colours continuou...

Page 11: ...Century Spot manual_Last Revision_en doc 11 14 ELECTRICAL DIAGRAM...

Page 12: ...4 pcs 030060019 230V 19W FAN 030060042 220V 50 60Hz LAMP 100050024 HMI 2500W SE CAPACITOR 4 pcs 140010018 60 F AC 370V MOTOR 030040029 17HS1013L MOTOR 030040097 17HS1013 10L IC1 230040093 Digital PCB...

Page 13: ...Century Spot manual_Last Revision_en doc 13 14...

Page 14: ...tury Spot manual_Last Revision_en doc 14 14 PR LIGHTING LTD No 571 Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 86 20 8478 1888 FAX 86 20 8478 6023 P N 320040047 Last Revision 02 08 2...