Century Spot manual_Last Revision_en.doc
5/14
When the power is switched on, the apparatus automatically starts to run the programmes of self-
test. After finishing these, the apparatus is ready for the following operation.
Remove the cover of the control panel. You will see the panel as shown in the figure below.
The right red LED flashes means there is a DMX signal receiving.
Press the button RESET to reset the DMX start address and functions, and the left green LED
will flash one time.
TO SET THE DMX START ADDRESS
See the panel above.
The digital screen will display the DMX start address.
Press the button UP or DOWN, you can change the start address.
Press the button ENTER to confirm. The green LED will flash one time, which means that
apparatus has saved your setting.
The setting will be displayed when you turn on next time.
In stand-alone mode, the DMX start address could be set any value. In master/slave mode, refer
to the chapter
MASTER/SLAVE MODE
. In controller mode, the address of each apparatus must
be set correctly so as to be controlled respectively. Refer to the chapter
CONTROLLER MODE
.
TO SET THE FUNCTION
Press the button FUNC consecutively, the digital screen will display in turn the function code 1~9,
A, b. Each one represents one function. You can see the following table for details.
When you locate the function code, you can press button UP or DOWN to display “y” or “n”.
When the digital screen display “y”, you can save and validate it via button ENTER. When the
digital screen display “n”, you can save and invalidate it via button ENTER.
OPERATION