9202QI01
LERBAKKEN 10, 8410 RØNDE DENMARK
Revision date:
2011-11-20
Version Revision
V4 R0
Prepared by:
PB
Page:
2/2
Ex input:
CH1 (terminal 41,42,43,44)
CH2 (terminal 51,52,53,54)
U
o
:10.6 VDC
I
o
: 12 mADC
P
o
: 32 mW
Lo/Ro:1150
H/
IIC
IIB
IIA
I
C
o.
2.0
F 6.0
F 18
F
90 µF
L
o.
260 mH
780 mH 1000 mH
1000 mH
Hazardous area
Non Hazardous area
Zone 0,1, 2, 20, 21, 22 or Zone 2
Terminal CH1(11,12) CH2(13,14)
Digital output:
NPN output:
Voltage max.
30 VDC
Current max.
80 mA
Terminal CH1(11,12) CH2(13,14)
Relay output:
Non Hazardous location
Zone 2 installation
Voltage max.
250 VAC / 30 VDC
32 V AC / 30 VDC
Power max.
500 VA / 60 W
64 VA / 60 W
Current max.
2 AAC / 2 ADC
2 AAC / 2 ADC
-20
≤
Ta
≤
60ºC
U
m
: 253 V max. 400 Hz
Supply / Output:
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
44
43
42
41
54
53
52
51
34
33
32
31
14
13
12
11
9202
4501
91 92 93 94 95
Power
Rail
CH1
CH2
+
-
+
-
NA
MUR S
enso
r
Switch
S
w
itc
h w
. S
hu
nt
Co
nt
act Se
nso
r
22
9202 - Versão do produto 9202-003