4512V100-UK 3
Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com
IECEx and ATEX installation in Zone 2
DEKRA 13ATEX0098 X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II 3 G Ex nA IIC T5 Gc
IECEx DEK 13.0026 X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ex nA IIC T5 Gc
For safe Ex installation the following must be observed:
The device must be installed by qualified personnel who are familiar with the national and international laws, directives and
standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
The devices must be installed in a suitable enclosure providing a degree of protection of at least IP54 according to EN60529,
taking into account the environmental conditions under which the equipment will be used.
To prevent ignition of the explosive atmospheres do not separate connectors when energized and an explosive gas mixture is
present.
To avoid the risk of explosion due to electrostatic charging of the enclosure, do not handle the units unless the area is known
to be safe, or appropriate safety measures are taken to avoid electrostatic discharge.For safe installation the following must
be observed
FM installation in Zone 2 / Div. 2
FM, US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL I, Div 2, Gp A, B, C, D T5
CL I, Zn 2, Gp IIC T5
FM, CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL I, Div 2, Gp A, B, C, D T5
For safe Ex installation the following must be observed:
The device must be installed by qualified personnel who are familiar with the national and international laws, directives and
standards that apply to this area.
CAUTION:
To prevent injury, read the manual before use.
WARNING
– Explosion hazard. Substitution of components may impair suitability for Class I, Division 2.
WARNING
– Explosion hazard. Do not disconnect while circuit is live unless area is known to be non-hazardous.
WARNING
– Explosion hazard. Do not disconnect equipment unless power has been switched off or the area is known to be
non-hazardous.
Year of manufacture can be taken from the first two digits in the serial number.
The equipment is intended to be mounted in a vent-free, tool-secured enclosure, meeting the equipment enclosure
requirements in accordance with ANSI/ISA-61010-1 and C22.2 No. 1010.1, where applicable.
Cleaning
When disconnected, the device may be cleaned with a cloth moistened with distilled water.
Warranty
PR electronics A/S offers a 5-year warranty on this product.
Liability
To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR
electronics A/S that would otherwise exist according to the concluded sales agreement.