background image

5333V113-UK

Output:
Current output:

Signal range ...............................................................   4...20 mA 

Min. signal range ......................................................   16 mA 

Updating time ...........................................................   135 ms 

Load resistance.........................................................  

 (V

supply

- 8) / 0.023 [

Ω

]

Load stability .............................................................   < ±0.01% of span / 100 

Ω

Sensor error detection:

Programmable ...........................................................   3.5...23 mA 

NAMUR NE43 Upscale ...........................................   23 mA

NAMUR NE43 Downscale .....................................   3.5 mA

Of span = Of the presently selected range

Approvals:

EMC ................................................................................  2014/30/EU

CCOE ..............................................................................  P337392/3

RoHS .............................................................................  2011/65/EU

EAC .................................................................................   TR-CU 020/2011

Marine approval:

DNV-GL, Ships & Offshore ....................................   Standard for Certification No. 2.4

Ex / I.S.:

ATEX 2014/34/EU

 5333A ......................................................................   KEMA 10ATEX0003 X 

  5333D......................................................................   KEMA 03ATEX1535 X

FM certificate ............................................................  FM17US0013X 

CSA certificate ..........................................................  1125003

IECEx .............................................................................   DEK 13.0036 X

INMETRO .....................................................................   DEKRA 16.0014 X

CCOE ..............................................................................  P337392/4

EAC Ex TR-CU 012/2011 .....................................   RU C-DK.GB08.V.00410

Summary of Contents for 5333

Page 1: ...5 3 3 3 CCOE 2 W i r e P r o g r a m m a b l e T r a n s m i t t e r N o 5 3 3 3 V 1 1 3 U K F r o m s e r n o 1 3 2 0 9 4 0 0 1 1 3 2 0 9 4 6 3 0 1 4 1 1 1 5 0 0 1 ...

Page 2: ...concerning revisions of this document Rev ID Date Notes 111 13 45 IECEx and INMETRO approvals added 112 15 14 PESO CCOE approval added GOST approval replaced with EAC approval 113 17 07 FM installation drawing updated INMETRO installation drawings updated ...

Page 3: ...s 7 Block diagram 8 Programming 9 Mechanical specifications 10 Mounting of sensor wires 10 Appendix 11 ATEX Installation Drawing 5333A 12 ATEX Installation Drawing 5333D 13 IECEx Installation Drawing 5333A 15 IECEx Installation Drawing 5333D 16 FM Installation Drawing 5333D 18 CSA Installation Drawing 5333D 20 INMETRO Instruções de Segurança 5333A 21 INMETRO Instruções de Segurança 5333D 22 ...

Page 4: ...n of linear resistance variation to a standard analogue current signal for instance from valves or Ohmic level sensors Technical characteristics Within a few seconds the user can program PR5333 to measure temperatures within all RTD ranges defined by the norms The RTD and resistance inputs have cable compensation for 3 wire connection Mounting installation For DIN form B sensor head mounting In no...

Page 5: ...5333V113 UK 3 APPLICATIONS V mA V mA RTD to 4 20 mA 2 wire installation in control room Resistance to 4 20 mA 2 wire installation in control room ...

Page 6: ...power dissipation Standard 25 mW 0 8 W CSA FM ATEX IECEx INMETRO 25 mW 0 7 W Voltage drop 8 VDC Warm up time 5 min Communications interface Loop Link Signal noise ratio Min 60 dB Response time programmable 0 33 60 s Signal dynamics input 19 bit Signal dynamics output 16 bit Calibration temperature 20 28 C Order 5333 Type Version 5333 Standard A CSA FM ATEX IECEx INMETRO D ...

Page 7: ... 60068 2 6 2007 2 25 Hz 1 6 mm 25 100 Hz 4 g Max wire size 1 x 1 5 mm2 stranded wire Humidity 95 RH non cond Dimensions Ø 44 x 20 2 mm Protection degree enclosure terminal IP68 IP00 Weight 50 g Electrical specifications input RTD and linear resistance input Max offset 50 of selec max value Cable resistance per wire max 10 Ω Sensor current 0 2 mA 0 4 mA Effect of sensor cable resistance 3 wire 0 00...

Page 8: ...A NAMUR NE43 Downscale 3 5 mA Of span Of the presently selected range Approvals EMC 2014 30 EU CCOE P337392 3 RoHS 2011 65 EU EAC TR CU 020 2011 Marine approval DNV GL Ships Offshore Standard for Certification No 2 4 Ex I S ATEX 2014 34 EU 5333A KEMA 10ATEX0003 X 5333D KEMA 03ATEX1535 X FM certificate FM17US0013X CSA certificate 1125003 IECEx DEK 13 0036 X INMETRO DEKRA 16 0014 X CCOE P337392 4 EA...

Page 9: ...5333V113 UK 7 CONNECTIONS 1 2 mA 3 4 6 3 4 6 3 4 6 3 4 6 Output 2 wire installation Input RTD 2 wire RTD 3 wire Resistance 2 wire Resistance 3 wire ...

Page 10: ...8 5333V113 UK BLOCK DIAGRAM 0 16 m A 1 3 6 2 mA M UX 4 m A 5333 PGA D A A D C PU E E PRO M DC DC 4 Supply 4 20 mA Input Input Supply 8 35 VDC Comp RTD Lin R Comm ...

Page 11: ...Loop Link PROGRAMMING 1 2 Loop Link 5909 USB File Product Input Output C ommunication Language Option 08 30 00 PRetop 5331 Date 2004 8 10 043201594 PRelectronics Analog input Analog output Serial no Inputtype Outputtype 4 20mA Upscale Sensor error Pt100 DIN IEC 0 00 50 00C 3 wire 1 00sec Inputrange Connection Cold junction comp Response time Tag no 5333 Receiving Equipment Disconnect Vsupply Black...

Page 12: ...20 2mm ø 6 mm 33 mm ø 44 mm 10 5333V113 UK Mechanical specifications Mounting of sensor wires Wires must be mounted between the metal plates ...

Page 13: ...X Installation Drawing 5333D IECEx installation drawing 5333A IECEx installation drawing 5333D FM Installation Drawing 5333D CSA Installation Drawing 5333D INMETRO Instruções de Segurança 5333A INMETRO Instruções de Segurança 5333D 5333V113 UK 11 ...

Page 14: ...e For type of protection Ex nA the transmitter shall be mounted in a metal enclosure providing a degree of protection of at least IP54 according to EN60529 For use in the presence of combustible dusts the transmitter shall be mounted in an enclosure providing a degree of protection of at least IP6X in accordance with EN60529 the surface temperature of the outer enclosure is 20 K above the ambient ...

Page 15: ...irectives and standards that apply to this area Year of manufacture can be taken from the first two digits in the serial number ATEX Certificate KEMA 03ATEX 1535 X Marking Standards EN 60079 0 2012 EN 60079 11 2012 EN 60079 26 2007 EN 60079 15 2010 Non Hazardous Area Hazardous area Zone 0 1 2 20 21 22 II 1 G Ex ia IIC T4 T6 Ga II 1 D Ex ia IIIC Da II 1 M Ex ia I Ma Terminal 3 4 6 Uo 27 VDC Io 7 mA...

Page 16: ...e excluded If the enclosure is made of non metallic materials electrostatic charging shall be avoided For installation in a potentially explosive dust atmosphere the following instructions apply The transmitter shall be mounted in a metal enclosure form B that is providing a degree of protection of at least IP6X according to EN60529 that is suitable for the application and correctly installed Cabl...

Page 17: ...ng a degree of protection of at least IP54 according to IEC60529 or in an enclosure with type of protection Ex n or Ex e For ic installation the transmitter must be installed in enclosure providing a degree of protection of at least IP20 according to IEC60529 and that is suitable for the application Cable entry devices and blanking elements shall fulfill the same requirements For an ambient temper...

Page 18: ...rectives and standards that apply to this area Year of manufacture can be taken from the first two digits in the serial number Certificate IECEx DEK 13 0036X Marking Standards IEC 60079 0 2011 IEC 60079 11 2011 IEC 60079 26 2006 Non Hazardous Area Hazardous area Zone 0 1 2 20 21 22 M1 Ex ia IIC T4 T6 Ga Ex ia IIIC Da Ex ia I Ma 1 2 6 5 4 3 Barrier 5333D 5343B Terminal 1 2 Ui 30 VDC Ii 120 mA Pi 0 ...

Page 19: ... it must be installed such that ignition sources due to impact and friction sparks are excluded For installation in a potentially explosive dust atmosphere the following instructions apply For explosive dust atmospheres the surface temperature of the outer enclosure is 20 K above the ambient temperature The transmitter shall be mounted in a metal enclosure form B according to DIN43729 that is prov...

Page 20: ...Po 67 2 mW Ca or Co 3 5 uF La or Lo 35 mH Ambient temperature limits T4 40 to 85 deg Celcius T6 40 to 60 deg Celcius Class I Division1 Groups A B C D T4 T6 Class I Zone 0 AEx ia IIC T4 T6 Non Hazardous Location Hazardous Classified Location Associated Apparatus or Barrier with entity Parameters SENSOR 1 2 3 4 5 6 UM 250V Voc or Uo Vmax or Ui Isc or Io Imax or Ii Po Pi Ca or Co Ci Ccable La or Lo L...

Page 21: ...hich the device can receive and remain intrinsically safe must be equal to or greater than the voltage Uo or VOC or Vt and current Io or ISC or It and the power Po which can be delivered by the barrier The sum of the maximum unprotected capacitance Ci for each intrinsically device and the interconnect ing wiring must be less than the capacitance Ca which can be safely connected to the barrier The ...

Page 22: ...C and D Class I Zone 0 AEx ia IIC Ga Warning Substitution of components may impair intrinsic safety The transmitters must be installed in a suitable enclosure to meet installation codes stipulated in the Canadian Electrical Code CEC or for US the National Electrical Code NEC Non Hazardous Area Hazardous area 1 2 6 5 4 3 Barrier Module 5335D 5336D and 5337D Terminal 3 4 5 6 Uo 9 6 VDC Io 28 mA Po 6...

Page 23: ...lucro com tipo de proteção Ex n ou Ex e Para a instalação Ex ic o transmissor deve ser instalado em um invólucro proporcionando um grau de proteção de IP20 pelo menos de acordo com a norma ABNT NBR IEC 60529 E o invólucro deve ser adequado para a aplicação e corretamente instalado Dispositivos de entrada de cabos e elementos de supressão devem cumprir os mesmos requisitos Para temperatura ambiente...

Page 24: ...nacionais diretrizes e padrões que se aplicam a esta área Ano de fabricação pode ser pego dos dois primeiros dígitos do número de série Certificado DEKRA 16 0014 X Marcas Normas ABNT NBR IEC 60079 0 2013 ABNT NBR IEC 60079 11 2013 Areas de não Risco Áreas Risco Zona 0 1 2 20 21 22 M1 Ex ia IIC T6 T4 Ga Ex ia IIIC Da 1 2 6 5 4 3 Barrier 5333D 5343B Terminais 1 2 Ui 30 VDC Ii 120 mA Pi 0 84 W Li 10 ...

Page 25: ... de materiais não metálicos cargas eletroestáticas devem ser evitadas Se o enclosure é feito de materiais não metálicos cargas eletroestáticas devem ser evitadas Para instalação em atmosfera de poeira potencialmente explosiva as instruções a seguir O transmissor deve ser montado em invólucro de metal forma B de acordo com DIN43729 que está fornecendo um grau de proteção de pelo menos IP6X de acord...

Page 26: ...alvanic isolators for analog and digital signals as well as HART signals A wide product range with both loop powered and universal isolators featuring linearization inversion and scaling of output signals Isolation Interfaces for analog and digital signals as well as HART signals between sensors I P converters frequency signals and control systems in Ex zone 0 1 2 and for some devices in zone 20 2...

Page 27: ...ales it prelectronics com www prelectronics se sales se prelectronics com www prelectronics com sales uk prelectronics com www prelectronics com sales us prelectronics com www prelectronics cn sales cn prelectronics com Head office Denmark www prelectronics com PR electronics A S sales prelectronics dk Lerbakken 10 tel 45 86 37 26 77 DK 8410 Rønde fax 45 86 37 30 85 ...

Reviews: