11
Delete:
Unforeseen circumstances during measurement, you need to delete a measuring point data, press
the "
→
" button to move to " Delete " and press the "OK" button, point number ( the number
behind " Site =" ) minus 1 , indicating that the point data is deleted.
Display
Press the OK button at " Display " option, the curve of this frequency ( specific frequency is the
number behind " Freq = " at this measuring line (specific line is the number behind Line =") will
be displayed on the screen. Then the status bar below display: “ Arrow Keys select Lines & Freq
(press the Left/Right button to select the measuring line, press the UP/Down button to select the
frequency). Press the "OK" button, the content displayed will be returned to the Tri-band Mode
interface as shown in Figure 4 above.
Export
After plug U disk into the USB port of instrument, select " Export" on the main screen and
press the OK button, then the status bar display: Start output data, until show " output the data to
USB sucess", before pull out U disk. If an error occurs and can not be transferred, for example due
to the U disk and the host does not recognize or U disk and host poor contact, then the status bar
will complain.
Return
Select " Return " and press the " OK " button, the graphics display content will be from Figure 4
Tri-band Mode back to Figure 2 main screen status.
Note: Please don’t shut down the instrument when it is measuring, otherwise it will cause data loss
or program confusion. Any other time you can shut down.
M N Electrode Description
The electrode with plastic rods and copper electrodes. Usage: As following Figure 5 to connect a
handheld plastic rod with copper electrodem inserted into the soil, the puddled soil is
recommended in each insertion. Before click on the "Record " , Press " Line Detection " firstly,
judged good grounding , Indicator lights up and then process measuring.
Note: On dry and hard ground, it’s difficult to use hand to penetrate the electrode, pls never
hammer the electorde into ground, it will broke the machine function. You can mix some water,
salt and soil in a barrel, then put the mud on the hard point so that you can insert the electrode.
Meanwhile, you need cover the line that you will measure with salt water to improve the electrical
conductivity.