background image

 

                                      

Pioneer Petrotech Services Inc. 

 

                  #1, 1431 – 40 Ave NE, Calgary, AB, Canada, T2E 8N6 

                                                                                                                    Tel: (403)282-7669, Fax: (403)282-0509  

 

PPS36 User Manual                                                                                                                       Page 

10

 of 

30 

  

 

2.3. 

Shortcut Buttons 

(See Figure 5) 

2.3.1. 

Power Button              

Touch and hold 

POWER

  for 3 

seconds to switch ON/OFF the DW.

 

2.3.2. 

Set Battery Capacity            

 

In Non-Record Mode (Default mode), 

touch 

Set Battery Capacity

 button. 

 

Touch “1” or “2” to select quantity of 

battery sets installed (each set includes 
two cells). 

Touch 

OK

 to accept or touch 

MENU

 to 

return.

 

2.3.3. 

Backlight Brightness          

 
In Non-Record Mode, touch 

Back Light 

button to enter Backlight Setting. 

 

Touch 

UP

/

DOWN

 to increase or decrease backlight brightness.  

Touch 

MENU

 to return.

 

2.3.4. 

Start/Stop Logging    

           

Touch 

Start/Stop Logging

  button to switch between Record Mode and Non-

Record Mode. 

 

Touch 

OK

 to switch Working Mode or touch 

MENU

 to return. 

Once the DW is switched to Record Mode, Record Icon will show up.

 

2.3.5. 

Set Depth                                 

 

In Non-Record mode, touch 

Set Depth

 button to go into setting initial depth menu. 

 

Touch 

UP

/

DOWN

 to move cursor. 

Touch number key to enter desired number in the highlighted digit. 
Touch 

OK

 to accept change or touch 

MENU

 to return. 

 
 
 
 

 

 

          Figure 5 

 

        

 
 

 

Shortcut 
button 

 

 

 
 
 
 
 
 
 
 
 
 
 

  

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 
 
 
 

Summary of Contents for PPS36

Page 1: ...6 Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 1 of 30 PPS36 Depth Watcher User Manual Rev 1 4 Pioneer Petrotech Services Inc Unit Q 1235 40th Ave NE Calgary AB T2E 6M9 Canada Phone 1 888...

Page 2: ...nnectors 9 2 3 Shortcut Buttons 10 2 3 1 Power Button 10 2 3 2 Set Battery Capacity 10 2 3 3 Backlight Brightness 10 2 3 4 Start Stop Logging 10 2 3 5 Set Depth 10 2 3 6 Set Direction 11 2 3 7 Add GRD...

Page 3: ...Calgary AB Canada T2E 8N6 Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 3 of 30 2 4 11 Set Time Date see Figure 11 23 3 Standalone Operation 24 4 Real Time Monitoring 25 5 Maintenance 26 6...

Page 4: ...3 282 0509 PPS36 User Manual Page 4 of 30 Revision History Revision Date Comments 1 0 2010 09 20 Initial release 1 2 2010 12 17 Information about accessories 1 3 2011 02 03 Add sheave angle descriptio...

Page 5: ...when the DW is recording data The DW can also be connected to a PC to form a data acquisition system for displaying and processing information in real time With flexible configuration and friendly us...

Page 6: ...ry Capacity 1 000 000 samples or 30hours 0 1second sample when all channels are active Data File format TXT PRN and CSV Communications USB Display LCD Graphic Display 320 X240 Line 1 Battery Bar recor...

Page 7: ...Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 7 of 30 2 Functions Description 2 1 DW Box Identification Figure 2 Cover Battery Cap Body Battery Cartridge Figure 1 Handle Bar Encoder Input C...

Page 8: ...Channel B can be changed in MENU Touch UP key and DOWN key to switch display mode between Figure3 and Figure 4 Touch MENU key can go into main menu or quit previous menu Figure 3 Battery Icon Depth Sp...

Page 9: ...Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 9 of 30 2 2 Connectors Definition 2 2 1 Encoder Connector 2 2 2 Channel A B and Tension Connectors Pin A Pin B Pin C Pin D Pin E Pin F GND 5VD...

Page 10: ...n 2 3 3 Backlight Brightness In Non Record Mode touch Back Light button to enter Backlight Setting Touch UP DOWN to increase or decrease backlight brightness Touch MENU to return 2 3 4 Start Stop Logg...

Page 11: ...e 11 of 30 2 3 6 Set Direction In Non Record mode touch Set Direction button to go into Change Depth Direction Touch OK to reverse Depth Direction or touch MENU return without saving 2 3 7 Add GRD In...

Page 12: ...can be got by reading an initial mechanical counter or initial value which the users expect o Check if the desired unit is the same as the DW display unit Touch OK to accept change and cursor will au...

Page 13: ...ification Stop running depth system Record the DW s start depth value Start running depth for at least 25m or 80 feet and then stop Record the DW s end depth value Check if the measured distance match...

Page 14: ...r Resolution Or touch MENU to return Select b Set Encoder Resolution and touch OK Use UP or DOWN to move cursor Touch number key to input number encoder resolution in a flashing digital bit o The enco...

Page 15: ...Calibrate Tension see Figure 6 1 By Hydraulic option See Figure 8 PPS36 Hydraulic Weight Indicator Figure 8 Bottom Sheave Configuration Hydraulic Three through Pressure sensor 4 20mA cable Sling to w...

Page 16: ...ht Indicator to Zero at ambient pressure Select a Set Low Tension value and touch OK Do not apply load or tension to the wireline or slickline Read the tension value from the Hydraulic Weight Indicato...

Page 17: ...40 Ave NE Calgary AB Canada T2E 8N6 Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 17 of 30 Tension Verification Apply any load to the wireline or slickline Compare PPS36 tension value and...

Page 18: ...PS36 User Manual Page 18 of 30 2 By maximum Load Option Figure 9 Bottom Sheave configuration Wireline or slickline tension is given Tr Tw 2 cos 2 PPS36 Wireline or slickline to top sheave tension Tw W...

Page 19: ...umber key to enter maximum load value in the highlighted digit Touch OK to accept change and cursor will automatically move to a Set Maximum Load Or touch MENU to return without saving Sheave angle co...

Page 20: ...ally move to a Set Maximum Load Or touch MENU to return without saving 2 4 4 Calibrate Channel B see Figure 6 Please refer to 2 4 3 Calibration Channel A 2 4 5 Set Alarms see Figure 6 Alarms can work...

Page 21: ...A Unit D Change Channel B Unit 1 Change Depth Units Three options are available Depth Speed a ft ft m feet minute b m m m meter minute c User Custom Unit Recalibration of depth is NOT necessary when...

Page 22: ...units For User Custom Unit Procedures Select c User Custom Unit and touch OK Touch UP or DOWN to move cursor Touch 5 or 0 to select char from A to Z Touch OK to accept change Or touch MENU to return w...

Page 23: ...esired number in highlighted digit Touch OK to accept change Or touch MENU to return without saving 2 4 10 Select Channels see Figure 10 Select Channel has five sub menus A Depth Channel B Tension Cha...

Page 24: ...isabled and Tension is active see figure 14 Depth speed Tension and Channel A are active but Channel B is disabled see figure 15 Depth speed Tension and Channel B are active but Channel A is disabled...

Page 25: ...DepthView software manual Connect USB cable to a PC see Figure 1 Power up the box and start the PC Run DepthView software Start real time monitor and the box will start to record data which channels...

Page 26: ...e toward battery cap Turn battery cap clockwise to lock battery External Power Supply External power adaptor and battery sets can be used at the same time or separately If one set of battery is not ca...

Page 27: ...oder cable if it is broken or loosened c The tension value does not change when the tool string is going down or up Check the tension cable if it is broken or loosened d Cannot connect to a PC by usin...

Page 28: ...e 28 of 30 7 Parts and Accessories Item Part number Name Qty 1 01 AC 1100 A Encoder cable 20feet 1 2 01 AC 1101 A 4 20mA cable 15feet 1 3 3 01 AC 1106 A Pressure sensor 1000psi 1 3 4 01 AC 0012 A5 SAF...

Page 29: ...36 User Manual Page 29 of 30 8 01 AC 1115 A 12Vdc power adapter FWC3012F 1 9 01 AC 1103 A Power extension cable 1 feet 1 10 01 AC 1109 A Tip 2 11 01 AC 1105 A Encoder T connector 1 12 01 AC 1117 A Enc...

Page 30: ...Pioneer Petrotech Services Inc 1 1431 40 Ave NE Calgary AB Canada T2E 8N6 Tel 403 282 7669 Fax 403 282 0509 PPS36 User Manual Page 30 of 30 16 01 AC 1174 A 1 4NPT Three T 1 17 Pelican case 1...

Reviews: